DEIONIZING AIR BLOW GUN

SER-24

More than 2,000V AC high voltage is dealt with the product, therefore, be sure to read this manual before using the product to fully understand the functions
of this unit.
Keep the manual for future use.

■ 

Residual risk

Residual risk map requiring protective measures by the product user
Model: "

 DEIONIZING AIR BLOW GUN

SER-24

"

Residual risks are classified and described according to the definition below.

DANGER

Indicates that a person is likely to die or be seriously injured if protective measures are not implemented.

WARNING

Indicates that if the warning is neglected, it may result in death or serious injury.

CAUTION

Indicates that if the caution is neglected, it may result in injury or property damage.

The symbols and numbers of the parts shown in the figure correspond to those listed in the "List of Residual Risks" of this product. For details on each residual risk, 
refer to "Residual Risk List".

Residual risk where parts on the equipment 
are not identified

DANGER

Warning

No.2,No.3,No.6

Caution

L

oc

ati

on 

B

DANGER

Warning

No.5

Note

L

oc

ati

on 

A

DANGER

Warning

No.4

Note

L

oc

ati

on

C

DANGER

Warning

No.1

Caution

Optional

Air tube

Gun body

Power input cable (3M)

AC Adapter

Air inlet

To Air source

Summary of Contents for SER-24

Page 1: ...ely to die or be seriously injured if protective measures are not implemented WARNING Indicates that if the warning is neglected it may result in death or serious injury CAUTION Indicates that if the caution is neglected it may result in injury or property damage The symbols and numbers of the parts shown in the figure correspond to those listed in the List of Residual Risks of this product For de...

Page 2: ...o not use it in an enclosed space Otherwise the ozone concentration in the enclosed space may increase resulting in the development of chronological bronchitis etc A high voltage is applied to the electrode needle Do not put any conductive objects such as fingers body wires and tools closer to the electrode needle Failure to do so may cause an electric shock or malfunction The electrode needle has...

Page 3: ... Indoor altitude 2000m or less Usage Environmental Temperature 0 40 Usage Environmental humidity 15 65 unless no condensation Indicators Green Power supply normal Red Decrease in output power Ozone generation 0 04 ppm or less 200 mm from the spout air pressure 0 3MPa Ion balance Within 30V Material Body PBT Nozzle PPS Accessories Instruction manual this manual AC adapter Power cable 3 Numerical va...

Page 4: ...nit or the nozzles will become dirty lowering the electrostatic elimination performance and causing deterioration of the main unit Secure a work space when installing this product Also secure enough space to remove the AC adapter and cable Installation This product is an electrostatic eliminator that can be freely used by holding it in hand but it is convenient to install it by a method such as ha...

Page 5: ... will increase due to the electric discharge which may adversely affect the equipment and the environment Never make the nozzle at the gun tip which is connected to the internal circuit touch any conductor or live cable It may cause electric shocks or malfunction CAUTION Piezoelectric ceramics are built into the air gun Avoid dropping or impacting It will be the cause of the failure Do not use oth...

Page 6: ...he electrode needle be sure to use the screwdriver for the electrode needle sold separately in combination and set the tightening torque to 15 to 2 0 N cm at the time of replacement If the torque is not correct the screws of the main unit may be damaged Other inspections Area part to be Inspected Details of inspection Inspection method Inspection frequency Treatment of the issue found Power input ...

Page 7: ...7 3176 Shinyoshida cho Kohoku Ku Yokohama 223 8501 Japan No T1094 00 ...