FRYER PREPARATION FOR USE

“BOIL OUT” INSTRUCTIONS

New 

ANETS

  

Fryers are leak-tested and cleaned

at the factory before shipping.  Before using a
newly installed fryer for food preparation, clean the
kettle again, as follows:

1. Thoroughly wipe the interior of the kettle

with clean cloths.  Open the front door on
the lower portion of the fryer to access the
drain ball valve. Open the drain ball valve
(by aligning the valve handle with the drain
ball valve) and wipe the entire drain line clean.

2. Close the drain ball valve (turn the valve han-

dle cross-wise to the drain ball valve).  Fill
the kettle with water to about 3

“ 

from the

top.  Add 1 to 2 cups of soap powder,
washing soda (trisodium phosphate), or
deep fat fryer kettle cleaner.

3. Perform the Lighting Procedure for the

fryer.  (Refer to the Lighting Procedure
later in this manual.)

4. Set the thermostat to 190

°

F.  Heat, but DO

NOT boil the water.  Stir the water to dis-
solve the cleaning material.

7. Open the front door and mount the drain

extension to the drain ball valve.  Position a
container (bucket) capable of  holding VERY
HOT cleaning solution beneath the end of the
drain extension to hold the cleaning solution
being drained, as shown in Figure 5.

FRYER PREPARATION FOR USE

(Continued)

FRYER  OPERATING  INSTRUCTIONS 

(Continued)

Figure 5.  Draining The Kettle

8. Open the drain ball valve SLOWLY, to avoid

splashes while draining the cleaning solution
from the kettle.

9. Close the drain ball valve (valve handle

crosswise) and remove the drain extension.
Close the front door.

10. Safely dispose of the cleaning solution.

11. Fill the kettle with water to about 3

 from

the top.  Add 2 cups of vinegar to neutralize
the cleaning solution.

12. Repeat steps 3 through 10 of this procedure.

13. Thoroughly wipe the interior of the kettle and

the drain ball valve with clean, dry, wiping
cloths to remove ALL water.

14. Dry the kettle thoroughly because any re-

maining water can cause sputtering of  hot
shortening when the kettle is later filled and
heated.

5. Clean the fryer kettle for at least 20 minutes.

Use a small hand mop (an optional brush can
 be ordered for this purpose) to clean the
upper portion of the kettle (above the 3

waterline) and the top rim of the kettle.

6. Shut down the fryer using the Shutdown

Procedure for the fryer.  (Refer to the Shut-
down Procedure
 later in this manual.) Allow
the water to cool slightly.

!

WARNING

Hot cleaning solution can cause severe
burns.  Take care when handling hot clean-
ing solution to avoid spilling or splashing the
solution.

CAUTION

For fryers with built-in filter systems, DO NOT
pump the cleaning, or rinsing, solution through
the filter system, to avoid damaging the filter
system pump.

!

Summary of Contents for 14G

Page 1: ...gas Post this information in a prominent location FOR YOUR SAFETY DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance DANGER Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing th...

Page 2: ...Instructions 9 GasConnectionInstructions 10 FryerOperatingInstructions 11 Fryer Preparation For Use Boil Out Instructions 12 Figure 5 Draining The Kettle 12 LightingProcedure 13 Figure 6 Gas Safety Valve Control Knob Positions 13 Shutdown Procedure 14 Food Product Frying Time Chart 15 DailyCleaningProcedure 16 MonthlyMaintenanceInstructions 17 FryerTroubleshootingGuide 18 22 Fryer Warranty 23 DANG...

Page 3: ...rton for this fryer include 2 Fryer Baskets 1DrainValveExtension 1 Screen 4 Adjustable Legs 1 Cleanout Rod 1 Basket Hanger Other optionalequipment includes a sediment tray single or triple baskets a built in Filtronic II or Filter Mate under fryer filter system a fryer cover a drain table a front drain tray or four casters Model Features 14G Plain Steel Fryer Kettle 14GS Stainless Steel Fryer Kett...

Page 4: ...11 W C minimum INPUT REQUIRED SUPPLY PRESSURE MANIFOLD PRESSURE 111 000 BTU BTU Hr Rating is based on sea level operation For sites above 2000 feet reduce this rating 4 for each 1000 feet above sea level W C Inches Water Column Measure Supply Pressure when all other gas powered equipment is operating Gas Supply Inlet Pipe size must be NPT National Pipe Thread standard gas line The gas supplyinletl...

Page 5: ...r CAN CGA 6 16 latest edition and a quick disconnect device that complies with the Standard for Quick Disconnect Devices for Use with Gas Fuel ANSI Z21 41 or CAN CGA 1 6 9 latest edition d Restrict the movement of a caster equipped fryerbyusingalimitingdevice forexample a cable attached both to the fryer and to a fixture attached to the site structure to avoid depend ing on the connector and the q...

Page 6: ...r casters to the bot INSTALLATION REQUIREMENTS tom of the fryer using the supplied hardware to preventthefryerfromtipping wobblingor rockingwhenitisinitsdesiredlocation Refer tothefollowingInstallationInstructionsforleg orcasterattachmentandlevelinginformation 4 Confirmthattheairfromtheventilationhood flowingnearthefryerafterinstallationisNOT blowing on the rear of the fryer to prevent affectingth...

Page 7: ...gisevident 3 Perform the Fryer Restraining Device Installation Instructions LEG INSTALLATION INSTRUCTIONS 1 Flattentheshippingcarton afterunpackingthe fryer and its parts and accessories for surface protectionduringleginstallation 2 Position the side of the fryer flat on the carton exposingthefryerbottommountingbrackets forleginstallation asshowninFigure3 3 Placethelegmountingplateflushagainstthe ...

Page 8: ... INSTALLATION INSTRUCTIONS Continued CASTER INSTALLATION INSTRUCTIONS 1 Flattentheshippingcarton afterunpackingthefryerand its parts and accessories for surfaceprotectionduringleg installation 2 Positionthesideofthefryerflat on the carton exposing the fryerbottommountingbrackets forcasterinstallation asshown inFigure4 3 Placethecastermountingplate flushagainstthemountingbrac ket on the fryer botto...

Page 9: ...desiredlocation 1 Installonerestrainingdeviceconnector into thestructurewalldirectlybehindthefryer s desired location as shown in Figure 2 2 Installonerestrainingdeviceconnectoronthe rear panel of the fryer very close to the quick disconnect device on the end of the fryer s gas line 3 Attach one end of the restraining cable to the wall connector Attach the other end to the fryerconnector 4 Confirm...

Page 10: ...lyinletlinevalveis closed cross wise to the pipe line direction 3 Ensure that all fryer controls are set to OFF 4 Connectthe gassupplylinetothegasline adapter on the lower rear of the fryer 5 Turn the gas supply line valve ON then con firmthatallgassupplylinejointsandcouplings are free of leaks using soap suds or a leak check solution after the fryer is in its desired location 6 Refer to Fryer Ope...

Page 11: ...eworkingonit toprevent burns D Contact the factory 800 837 2638 for war rantyserviceauthorization Alwaysnotify the factory the next business day about after hours warranty service Contact yourlocalrestaurantequipmentservice agency for other service repairs or mainte nanceactivities asnecessary E When breaded food products are being cooked ANETS recommends using the special optional sedimenttraytoc...

Page 12: ...tinued FRYER OPERATING INSTRUCTIONS Continued Figure 5 Draining The Kettle 8 Open the drain ball valve SLOWLY to avoid splashes while draining the cleaning solution from the kettle 9 Close the drain ball valve valve handle crosswise and remove the drain extension Close the front door 10 Safely dispose of the cleaning solution 11 Fill the kettle with water to about 3 from the top Add 2 cups of vine...

Page 13: ...gout 6 Release the control valve knob and observe thatthepilotflameremainslighted Closethe rightpilotviewing lighting port 7 Lighttheleftpilotflamebyopeningtheleft pilotviewing lightingportandapplyinga matchtoignitethepilotflame Closethe leftpilotviewing lightingport FRYER OPERATING INSTRUCTIONS Continued Figure 6 Gas Control Valve Knob Positions OFF PILOT ON Valve Mark 8 Turnthegascontrolvalvekno...

Page 14: ...ermostat knob to OFF 2 Turnthegascontrolvalveknobtoalignthe PILOTsettingwiththevalvemark FRYER OPERATING INSTRUCTIONS Continued SHUTDOWN PROCEDURE 3 Openthepilotviewing lighting porttocon firmthatonlythepilotflameremainslighted 4 Press down and turn the gas control valve knob to align the OFF setting with the valve mark Observe that the pilot flame goes out NOTE For extended periods of non use orw...

Page 15: ...lower quality product and will cause more rapid shortening break down RECOMMENDED FRYING TIME FOR POPULAR FRIED FOODS Food Product Typical 1 lb load Breaded Foods Calamari Cheese Sticks Fresh Shrimp Breaded Frozen Shrimp Breaded Mushrooms Onion Rings Tamale Sticks Chicken Croquettes Nuggets Pre cooked Breaded Pieces Raw to Done Pieces Tenders Corn Dogs French Fries Raw to Done 1 4 cut Blanched onl...

Page 16: ...e hot shortening to avoid burns Thor oughlyclean andrinse theseitemsinthe sink MAKE SURE that these items are completelydrybeforetheirnextuse FRYER OPERATING INSTRUCTIONS Continued 5 Allowtheshorteningtocoolbeforedraining Slowlyopenthedrainballvalvetodrainthe shortening Take care to avoid spilling or splashingtheshortening 6 Carefully use the Cleanout Rod to clear any sedimentblockingthekettledrai...

Page 17: ... NEVERallowthefluetobe blocked Monthly observetheconditionoftheventilation hood If it shows evidence of a great deal of greasy residue remove clean the residue to allow freeflowofventilationair MONTHLY MAINTENANCE INSTRUCTIONS FRYER OPERATING INSTRUCTIONS Continued 12 Return the screen or if used the sediment tray to its proper position in the kettle Place the fryer baskets on the basket hanger re...

Page 18: ... in crease the flame size Un screw and retain the slotted threaded cover turn the pilot valve adjustment screw two turns counterclockwise reinstall the threaded cover 4 Block or redirect the draft to keep the flame burning steadily 5 Replace the thermocouple 6 Check for and repair any dam aged high limit thermostat wir ing For model 14GSU fryer ONLY Press the reset push button on the high limit th...

Page 19: ...at wir ing For model 14GSU fryer ONLY Press the reset push button on the high limit thermo stat control Perform the Light ing Procedure to check wheth er the pilot flame lights If the pilot flame stays lit the high limit thermostat has failed and must be replaced Pilot flame does not stay lighted Continued 6 High limit thermostat problem has shut off the gas Continued 7 Gas control valve has faile...

Page 20: ...Burner problems and use the correct remedy 4 Increase the thermostat setting until the burners light If this setting is greater than the de sired temperature reset the thermostat to the desired set ting and allow the shortening to cool to the desired tempera ture 5 Replace the gas control valve CAUTION DO NOT return the fryer to normal operation with its high limit thermostat bypassed disconnected...

Page 21: ...ffers by about 10 F from measured shortening temperature 1 Measure the gas supply pres sure Contact your local gas supplier to obtain adequate gas supply pressure 2 Measure the gas pressure at the fryer s manifold pressure tap Adjust the manifold pres sure see Figure 6 as neces sary a Unscrew and re tain the threaded Main Burner Regulator Adjustment Cover b Use a flat blade screwdriver to turn the...

Page 22: ... the thermostat setting Tighten the brass hex nut to lock the adjustment Replace the cap on the knob 4 Check the thermostat setting against an accurate measure of the shortening temperature If the temperature difference is greater than 20 F the thermo stat can possibly be recali brated Recalibrate the thermostat by a removing the cap on the thermostat control knob b loosening the center brass hex ...

Page 23: ...lacementpartwithinthesameperiod Allfrypotsarecoveredbythewarrantyaboveforthefirstyearofoperation Various models have an extended warranty that covers the replacement of thefrypotonly Seetheindivdualspecificationsheetsfordetails Overtimecharges calibration adjustmentsandabnormalinstallationcharges shall not be at the expense of Anetsberger Brothers Inc The conditions and warranty expressed above ar...

Page 24: ...North Anets Drive Northbrook Illinois 60062 847 272 0770 Fax 847 272 1943 Toll free Customer Warranty Service 800 837 2638 www anetsberger com Keep this Manual in a Convenient Location for Reference Form I 102 Rev 10 01 Price 20 00 US ...