11 

 

 

 

 

 

 

 

 

 

 

Filter Setup

 

 

Up  Arrow  

 

Down  Arrow 

 

 

 

STEP 1S

 

STEP 1S 

– 

Press NEXT and  

 

simultaneously for 3 seconds.  If screen in Step 2S  does not 

appear in 5 seconds the  lock  on  the  valve  is activated. 

 

 
 

 

 

FILTERING

 

SET 

TYPE

 

 
 
 

 

 

BACKWASH TIME

 

SET     

12:00

MIN

 

 

 

 
 

 

RINSE TIME

 

SET 

6:00 

MIN

 

 
 
 

 

 

DRAW DN TIME

 

SET 

13:00 

MIN

 

 

 

 
 

 

 

GALLONS CAPACITY 

SET 

OFF

 

 

 
 

 
 
 
 

DELAYED

 

 

STEP  2S 

STEP  3S 

STEP  4S 

STEP 5S

 

 

STEP 6S

 

 
 
 
 
 
 
 
 
 

 

STEP 7S

 

STEP 2S 

– 

Select between softening or filtering.   

A flashing  "SOFTENING"  or 

"FILTERING"  will appear.  Choose FILTERING using  

 

or 

 

button.  

Factory setting is Filter- 

ing. 

Press NEXT to  go  to  Step 3S.   Press REGEN to  exit  Filter System Setup. 

 
 
 
 

 

STEP 3S 

– 

Select the  time  for the  first  cycle 

(which  in this  example is BACKWASH) using  the 

 

or 

 

button.  Press NEXT to  go  to  Step 4S.   Press REGEN to  return  to  previous step. 

 

 
 
 
 
 

STEP 4 S 

– Select the time for the second cycle 

(which  in this  example is RINSE) using  

 

or 

 

button.  Press NEXT to  go  to  Step 5S.   Press REGEN to  return  to  the  previous step. 

 
 

 
 
 

 

STEP 5 S 

– Select the time for the third cycle 

(which  in this  example is DRAW or  AIR RE

CHARGE) using  

 

or 

 

button.  Press NEXT to  go  to  Step 6S.   Press REGEN to  return  to  the 

previous step. 

 
 
 
 

 
 

STEP 6 S 

– Set Gallons Capacity 

using  

 

or 

 

button.  If value  is set  to: 

• “oFF” regeneration will be  based solely  on  the  day  override  set  (see  Installer Display/Settings 
Step 3,  page 6 or 
• as  a  number of gallons  (allowable  range 20  to  250,000)  regeneration will be  based on  the 
value  specified. 
Increment increase is 20  for the  range 20  to  2000,  100  for the  range of 2000  to  10,000 and  500 
for the  range of 10,000 to  50,000 and  2000  for range of 50,000 to  250,000. 
Press NEXT to  go  to  Step 7S.   Press REGEN to  return  to  previous step. 

 

 

 

STEP 7 S 

– Set Regeneration Time Options 

using  the 

 

or 

 

button. If value  is set  to: 

• “DELAYED” means regeneration will occur at  the  preset  time; 

 

SET

 

REGEN

 

• “IMMEDIATE” means regeneration will occur  immediately when  the  gallons  capacity reaches 
0 (zero); or 
• “D IMMEDIATE” means regeneration will occur at  one  of the  following: 
- the  preset time  when  the  gallons  capacity falls below  the  reserve or  the  specified number  of 
days  between regenerations is reached,  whichever comes  first; or 
- immediately after  10  minutes of no  water  usage when  the  gallon  capacity reaches 0 (zero). 

Factory Setting is Delayed

.  Press NEXT to  go  to  Step 8S.   Press REGEN to  return  to 

previous step. 

Summary of Contents for PurAzone A03

Page 1: ...PurAzone A03 Filtration PurAzone A03 Filtration Filter Manual Owner s Filter Manual 2013 2014...

Page 2: ...that you need professional assistance for servicing your water filter please contact the dealer who installed this system Table OF Contents Job Specification Sheet Page 3 General Specifications 3 Pre...

Page 3: ...se Bib Front Hose Bib Kitchen Cold Toilets All Cold Other INSTALLATION DATE SERIAL NUMBER NOTES Operating Pressures General Specifications Minimum Maximum 30 psi 120 psi Operating Temperatures Minimum...

Page 4: ...onnected per local codes Surge protection is recommended with all electrical controls existing Plumbing Condition of existing plumbing must be free from lime and iron build up Piping that is built up...

Page 5: ...5 Figure 2 Figure 4...

Page 6: ...ings bypass valve or control valve 4 a jumper ground wire should be installed between the inlet and outlet pipe whenever the metallic continuity of a water distribution piping system is interrupted In...

Page 7: ...ls vary depending on barometric pressure Manganese Limit 1 0 ppm amounts present over 1 0 ppm may gradually prevent iron removal Note For optimum manganese reduction pH should be greater than 8 5 Orga...

Page 8: ...7 Iron Blaster 10 Iron blaster 12 Iron blaster 13 10 x54 12 x52 13 x54 1 0 1 6 2 35 1 1 1 4 6 7 5 3 7 5 10 1 Water temps above 60 F will require a higher backwash rate Consult factory...

Page 9: ...ugh a regeneration cycle Capacity remaining is the number of gallons that will flashes in upper left corner of display between rotating display when RE GEN button pushed once GPM Flashes when the turb...

Page 10: ...r three seconds The system will begin to regenerate immediately The request cannot be cancelled You must cycle all the way through the cycles to make it stop PLEASE NOTE This will reset the meter rege...

Page 11: ...ween regenerations If value set to oFF regeneration initiation is based solely on gallons used If value is set as a number allowable range from 1 to 28 a regeneration initiation will be called for on...

Page 12: ...XT to go to Step 6S Press REGEN to return to the previous step STEP 6 S Set Gallons Capacity using or button If value is set to oFF regeneration will be based solely on the day override set see Instal...

Page 13: ...t be shown Factory setting OFF Press NEXT to go to step 21S or other selection screens for relay settings RELAY 1 SET POINT STEP 9S STEP 9 S If off was selected in previous step this screen does not a...

Page 14: ...13 NEXT to go to Step 15S...

Page 15: ...that amount Range 20 to 500 minutes REGEN is also an option for lockout Relay initiates 2 minutes prior to regen and completes 1 minute after regen Access REGEN setting by pushing down arrow through a...

Page 16: ...o to Step 3D Press REGEN to exit Diagnostics SINCE LAST REGEN 342 GAL RESERVE HISTORY STEP 3D STEP 4D STEP 3D Volume since last regeneration This display shows gallons of water that has been treated s...

Page 17: ...ess and simultaneously for three seconds and release then press and simultaneously and release If screen in step 2VH does not appear in 5 seconds the lock on the valve is activated TOTAL DAYS 970 STeP...

Page 18: ...17 RETURN TO NORMAL MODE...

Page 19: ...CS OFF Factory Setting is OFF Press NEXT to go to Step 10CS alTernaTOr SYSTeM STeP 4cS STeP 4cS Twin alternating System Allows automatic alternation between two units to provide SeT alT a filtered wat...

Page 20: ...16 NEXT to go to Step 10CS...

Page 21: ...Step 11CS STeP 8cS Configuring the Control Valve for Water Reclamation Mode Select Reclama tion Enabled for control operation Motorized Alternating Valve will advance to Bypass at a set time after the...

Page 22: ...REGEN If the dP switch is closed a regeneration will be prevented from occurring OFF Factory setting is off Press NEXT to go to Step 14CS Press REGEN to return to previous step bacKWaSH SeT cYcle 1 rI...

Page 23: ...tached to board if not replace transformer Error Code 103 Motor ran too long C1 High drive forces on piston C1 Loosen drive cap gear 1 4 turn timed out trying to reach next position C2 Address high dr...

Page 24: ...20 place If not replace stack assembly B2 Mechanical Binding B2 Drive gear and reducing gears should spin freely replace if necessary...

Page 25: ...C D E Power outages Time of day not set correctly Time of regeneration incorrect Control valve set at on 0 immediate regeneration Control valve set at NORMAL on 0 A B C D E Reset control valve to cor...

Page 26: ...rror 106 107 or 116 117 occurs and the valve has not entered regeneration Ozone Generator Spare Replacement Parts Denotes recommended spare maintenance parts Followed by quantity per unit recommended...

Page 27: ...ate Distributor Part of Vortech Tank 7 Bypass Valve 1 101325 8 Inline Check Valve Kit 1 104174 includes 90 vertical adapter inline check valve 9 Ozone Generator 1 110110 10 Check Valve 1 110239 11 Tan...

Page 28: ...and plug back in This resets the electronics and establishes the service piston position The display should flash all wording then flash the software version ex 214 and then reset the valve to the se...

Page 29: ...jector Screen Injector Plug and O Ring 1 2 3 4 5 The injector plug and the injector each contain one 011 lower and 013 upper o ring Note For upflow position injector is located in the up hole and inje...

Page 30: ...019 1 6 102406 DLFC Retainer Assy 1 7 101591 101595 101598 101561 DLFC 5 3 gpm for 3 4 DLFC 7 5 gpm for 3 4 DLFC 9 0 gpm for 3 4 DLFC 10 0 gpm for 3 4 1 One DlFC must be used if 3 4 fitting is used D...

Page 31: ...Ring 2 3 102165 O Ring 215 2 4 102450 Bypass 1 Rotor 2 5 V3146 Bypass Cap 2 6 V3147 Bypass Handle 2 7 109479 Bypass Rotor Seal Retainer 2 8 102159 O Ring 135 2 9 102161 O Ring 112 2 10 102160 O Ring 2...

Page 32: ...cap Do not use a pipe wrench to tighten or loosen nuts or caps Do not place screwdriver in slots on caps and or tap with a hammer Do not use pipe dope or other sealants on threads Teflon tape must be...

Page 33: ...der nO deScrIPTIOn QTY 1 102141 Nut 1 Quick Connect 2 2 102437 Split Ring 2 3 102165 O Ring 215 2 4 106769 Fitting 3 4 Brass Sharkbite 2 1 4 110135 Fitting 3 4 Brass Sharkbite Asy Set of 2 1 4 1 4 1 2...

Page 34: ...28...

Reviews: