- 9 -
3269830_ut_GB_rev.2
ENGLISH
GB
Lighting
1)
Operate the appliance’s master switch to con-
nect it to the electrical mains.
2)
Turn on the water supply tap.
3)
Turn on the gas supply tap.
Important
Before fi lling the tank, make sure the drain
lever is on “CLOSED”.
4)
Turn the knob
(A)
clockwise (pos.
3
) to fi ll the
tank in automatic mode, to the max level
The light
(C)
goes out.
5)
Press and turn the knob
(E)
anti-clockwise
(pos.
1
) to turn on the pilot light. Hold the knob
down for approximately15 sec. to start up the
thermocouple.
6)
Press the knob
(E)
and turn it anti-clockwise
(pos.
2
) to light the burner.
7)
Turn the knob
(B)
to one of the other positions
( pos.
5
) to adjust the burner intensity to lower
values.
Turning off
1)
Turn the knob
(B)
anti-clockwise (pos.
2
) to turn
off the electricity supply.
2)
Turn the knob
(A)
anti-clockwise (pos.
1
) to
stop delivery.
3)
Press the knob
(E)
and turn it clockwise (pos.
3
)
to turn off the burner.
The pilot light will remain on to allow the
burner to be re-lit.
4)
Press the knob
(E)
and turn it clockwise (pos.
4)
to turn off the pilot light.
5)
Turn off the gas and the water supply tap and
switch off the main electricity supply.
Important
Drain the well completely after use.
3
1
2
3
1
2
3
1
2
3
4
5
A
B
C
D
A
B
1
2
SWITCHING THE APPLIANCE ON AND OFF
1
2
3
4
E