- 13 -
3269830_ut_GB_rev.2
ENGLISH
GB
Faults
Causes
Remedies
Smell of gas
Occasional leak because fl ame
has gone out.
Turn off the gas supply tap and
ventilate the room.
The pilot light does not ignite.
The spark ignition devices are
not working.
Check that the ignition devices are
in good working order
.
Contact the after-sales service.
Air in pipelines due to long
period out of use.
Make more attempts to light the
fl ame.
The pilot light goes out.
The thermocouple has not
warmed up enough.
Make more attempts to light the
fl ame.
The fl ame is yellow.
Burner dirty, heat exchange
pipes clogged, condensation
drips.
Contact the after-sales service.
When the water control
knob is turned to
1
(auto-
matic rapid fi lling), water is
supplied continuously, until it
overfl ows.
Blockage in pressure switch
circuit..
Contact the after-sales service.
Pressure switch faulty.
Filler solenoid valve faulty.
When the water control knob
is turned to
1
(automatic
rapid fi lling), no water comes
out of the tap.
Pressure switch connection not
made correctly.
Check the pressure switch con-
nection.
Contact the after-sales service.
Water connection not made
correctly.
Check the water connection.
Contact the after-sales service.
When the water control knob
is turned to
2
(Slow automa-
tic top-up), slow fi lling does
not take place.
Water level maintenance sole-
noid valve connection not made
correctly.
Check the solenoid valve connec-
tion.
Contact the after-sales service.
Water level maintenance sole-
noid valve faulty.
FAULT
TROUBLESHOOTING
The appliance has been tested before being put
into service. The information provided below
is intended to assist in the identifi cation and
correction of any anomalies and malfunctions
which might occur during use.
The user can solve some of these problems
himself, but for others specifi c technical
knowledge or skill is required, and so they must
only be carried out by qualifi ed staff with reco-
gnised experience acquired in the specifi c sector
of operation.
Important
For all requirements contact the agents or the
headquarters of Angelo Po which can be found
in the contacts section of the website http://
www.angelopo.com.