- 17 -
3269850_inst_GB_rev.2
ENGLISH
GB
To carry out this operation, proceed as follows.
1)
Turn off the gas supply tap..
2)
Open the hatch
(A)
.
3)
Cut the band clamp
(B)
and disconnect the
cable
(C)
.
4)
Disconnect the gas supply line
(D)
.
5)
Undo the screws
(E)
and remove the pilot light
unit
(F)
.
6)
Undo the screws
(G)
and replace the ignition
plug
(H)
and/or the body of the pilot light
(L)
.
To replace the thermocouple
(M)
proceed as
follows.
REPLACEMENT OF PILOT LIGHT UNIT COMPONENTS (0*1FR3G-1*1FR4G)
7)
Undo the screws
(N)
to remove the guard
(P)
.
8)
Unscrew the union
(Q)
and replace the ther-
mocouple
(M)
.
9)
Replace the guard
(P)
.
10)
Reassemble the pilot light unit
(F)
and
reconnect the gas supply line
(D)
and the
cable
(C)
.
11)
Close the door
(A)
when the operation is
complete.
EQUIPMENT DECOMMISSIONING, DEMOLITION AND DISPOSAL
When decommissioning the appliance, a seri-
es of procedures must be carried out to ensure
that the appliance and its components are not a
hindrance and are not easily accessible.
To ensure that the appliance cannot constitu-
te hazards for people or the environment, all
energy sources (electricity, etc.) must be discon-
nected and rendered unusable, and any liquids
present must be drained (lubricants, fl uids, etc.).
Place the appliance in a suitable area which is
not easily accessible, with barriers to prevent an-
yone from accessing it.
When scrapping, sort all components by chemi-
cal characteristics and dispose of them separa-
tely in accordance with the relevant legal requi-
rements.
Important
Do not dump non-biodegradable products,
lubricating oils, and non-metallic compo-
nents (rubber, PVC, resins, etc.) in the envi-
ronment. Dispose of them in compliance with
the relevant laws.
Q
P
N
D
A
H
L
M
F
G E
B
C