- 16 -
C1
39
60
33
00
_2
.fm
IT
AUS
SDE
FR
ES
CONVERSION OF THE GAS SUPPLY
The constructor has tested the appliance with its own
mains gas, identified by the sticker applied to the
nameplate.
If the type of gas to be connected is different from that
used for testing, proceed as follows.
1- Turn off the gas supply tap (
A
).
2 - Change the burner nozzle (see page 19).
3 - Change the pilot light nozzle (see page 19).
4 - Adjust the gas solenoid valves (see page17).
5 - Remove the sticker from the nameplate and ap-
ply the new one to identify the gas being used.
Important
On completion of the operation, make
sure that there are no gas leaks or mal-
functions.
If converting from Natural gas to Un-
iersal LPG make sure the Natural gas regu-
lator is removed.
A
IDM-3960200240.tif
A.po Convers_gas_aus.tif