ANGELUS SANITARY CAN MACHINE COMPANY
SERVICE NOTICE
9/9/99-18033004
5 of 14
Rev. 1 - 9/9/99
ILLUMINATED:THE TRABON RESERVOIR OIL LEVEL HAS FALLEN BELOW THE DESIGNED
LOW TRABON OIL LIGHT continued;
LOW LEVEL SWITCH ACTUATION POINT.
- REFILL SHOULD BE ON.
- SHORTLY AFTER THE FLASHING LIGHT THE TRABON REFILL ON LIGHT SHOULD START
FLASHING INDICATING A REFILL IS IN PROGRESS.
- THE LOW TRABON OIL LIGHT WILL BE EXTINGUISHED AS THE TRABON
RESERVOIR LEVEL IS RAISED.
*MANUAL OIL CYCLE PUSH BUTTON.
AMBER ILLUMINATED PUSH BUTTON WHICH STARTS THE TRABON OIL PUMP WHEN DE
PRESSED AND INDICATES THAT A RESET IS REQUIRED, BY THE FOLLOWING STATES.
A TRABON FAILURE HAS OCCURRED AND THE MANUAL OIL CYCLE PUSH
B U T T O N
MUST BE
DEPRESSED TO RESET THE SYSTEM.
NOTE: WHEN THE OIL CYCLE PROXIMITY SW. RESETS THE RETRACT AND EXTEND
OIL CYCLE TIMERS THE MANUAL OIL CYCLE PUSH BUTTON LIGHT WILL FLASH
AT THE CYCLE PROXIMITY SWITCH RATE AS LONG AS THE PB IS DEPRESSED.
OIL LUBRICATION SYSTEM
*OIL PUMP PUSH ON PUSH OFF BUTTON
GREEN ILLUMINATED PUSH BUTTON WHICH STARTS THE OIL FILTRATION PUMP WHEN
HELD
IN. THIS PB MUST BE HELD IN UNTIL THE OIL FLOW SWITCH SENSES OIL FLOW, AT
WHICH
TIME THE PLC WILL LATCH THE PUSH BUTTON LIGHT ON INDICATING THE PUMP IS
IN
OPERATION AND THE BUTTON CAN BE RELEASED.
IF THE OIL FILTRATION PUMP IS IN OPERATION A MOMENTARY PUSH WILL STOP THE PUMP.
ILLUMINATED:THE SEAMER OIL FILTRATION PUMP IS IN OPERATION.
FLASHING:
THE OIL FILTRATION SYSTEM PUMP IS OFF AND SHOULD BE STARTED.
*CHANGE OIL FILTER LIGHT
RED PILOT LIGHT WHICH INDICATES THE FILTRATION SYSTEM FILTERS ARE DIRTY AND
REQUIRE CHANGING OR THE SYSTEM HAS FAILED DUE TO HIGH PRESSURE, BY THE
FOLLOWING LIGHT STATES.
FLASHING:
THE FILTRATION SYSTEM PRESSURE HAS EXCEEDED 65 PSI.
THIS LIGHT FLASHING IS AN INDICATION THE FILTERS WILL NEED TO BE
CHANGED SOON.
ILLUMINATED:THE FILTRATION SYSTEM PRESSURE HAS EXCEEDED 75 PSI. THE FILTERS
MUST BE CHANGED NOW.
NOTE: A MECHANICAL INTERNAL RELIEF VALVE WILL COMPLETELY BYPASS THE
OIL
PUMP AT 95 PSI.
*OIL BOOST ON LIGHT