ANGELUS SANITARY CAN MACHINE COMPANY
SERVICE NOTICE
2 of 5
C.
Remove both Service Covers from the machine and wipe clean* the Upper Turret
Housing area. Disconnect the oil return line below the Housing and flush it out
to remove all contaminates.
*Caution: When cleaning out the Housing area, it is very important to not use high
pressure hoses or any forced cleaning solutions inside this area. Water will enter the
Upper Turret, settling into bearing cavities, and will not be drained out through the
plug. If this accidently happens, all 18 Seaming Spindles will have to
come out to drain water.
D. Turn off air pressure supply to the Drive Case before disconnecting return line at
Lower Turret Guard.