ANGELUS SANITARY CAN MACHINE COMPANY 3/12
SERVICE NOTICE
18043001
180S Seamer Discharge Table
D.
The Discharge Rail Trip Finger
mounted on top of the Discharge Rail
Upper must be loosened and moved off
to the side or will be broken when the
Seamer height is changed.
51S846 =
Discharge Rail Trip Finger
__S845 =
Discharge Rail Upper
E.
Locate Elevator Screw w/ Hex.
Extension on top of the machine.
To increase can height turn the Elevator
screw counter-clockwise. Use a 19mm or
3/4" socket with a "T" handle for
elevating.
7S826 =
Elevator Screw W/ Hex. Extension
CAUTION:
Do not raise the machine higher then 26 inches between Upper Turret
Housing bottom surface and the Base machined surface. The Elevator Screws
will have approximately one inch of threads left in each Column Insert.
2.
Remove the Base Side Cover
A.
Remove ten M10-1.5 X 35mm Hex.
Hd. Screws from the Base Side Cover.
3S854 =
Base Side Cover
B.
Inspect the Side Cover O-Ring.
39S815 =
O-Ring