Currently national standards enforceable in the installation country covering the installation and use of gas powered
equipment are to be respected, as are standards covering smoke dispersion and ventilation of enclosed areas, even
though gas detection equipment is installed.
Essential  element  for  the  correct  functioning  of  the  detector  is  its  correct  installation.
Following  the  suggestions  in  this  section  you  will  get  a  high  accuracy  combined  with  a  total  absence  of  false
alarms.
The GS911K  is  an  equipment  adapted  to  be  mounted  externally  on  a  wall.  Installing,  it  is  fine  to  use  ordinary
care  that  requires  an  electronic  device,  and  then:
- Install the detector away from sources of excessive heat.
- Avoid that liquids come into contact with the detector GS911K,  remembering that its external structure has degree
of protection IP42.

The detector should not be installed:
in environments where the temperature drops below 10 ° C or rises above 40 ° C.

The detector is equipped to detect different types of gases, and according to these, its must to be positioned at different
heights.
These heights are:
- 30 cm from the lowest point of the floor in order to detect

heavy gases (LPG, etc)

- 30 cm from the highest point of the ceiling in order to detect

light gase (Methane etc)

-  Install  detectors  from  1  to  4  m  from  gas  appliances

The  installation  of  the  detector  does  not  exempt  from  ...  ...  The  compliance  with  all  regulations
concerning  the  characteristics,  installation  and  use  of  gas  appliances.  The  ventilation  of  the  spaces  and  the
elimination  of  combustion  products  are  described  in  the  UNI  norms  according  to  ART.  3  LAW  1083  /  71
and  relevant  legal  provisions.

METHANE  gas  detector
max.  30  cm  from  the  ceiling

LPG  gas  detector
max.  30  cm  from  the  floor

Installation  measures  and  positioning

Cau tio n !!  Do   n o t  in s t all  th e
detector  near:  sinks,  air  intakes,
h eati n g  o r  air   co n diti o n in g
s ys tems , 

w in do ws  

an d

ventilation  devices.

Summary of Contents for Beinat GS911K

Page 1: ...0 VAC The elegance and the prestige that have always made BEINAT S r l stand out from its competitors together with the concept of home fitness comes the household gas detector GS911K detects through...

Page 2: ...ed and or specialized personnel Do not allow it to become wet The detector can be seriously damaged when immersed in water Do not drop it Heavy knocks or falls during transportation or installation ca...

Page 3: ...closing the two poles the relay will work at pulse in the sense that once tripped the alarm relay will close the C and NA contacts for about 90 seconds and then will reopen them This is needed to pre...

Page 4: ...ing switch appropriately identified as the detector sectioning device must be incorporated in the electrical system suitably located and easily accessible ATTENTION The relay is voltage free 1 2 3 4 5...

Page 5: ...2 3 4 5 LV LG LR Rel ay Buzzer Wiring 1 2 3 4 5 LV LG LR Rel ay Buzzer Wiring Elettrovalvola NC 1 2 3 4 5 LV LG LR Rel ay Buzzer Wiring 1 2 3 4 5 LV LG LR Rel ay Buzzer Wiring 1 2 3 4 5 LV LG LR Rel a...

Page 6: ...should not be installed in environments where the temperature drops below 10 C or rises above 40 C The detector is equipped to detect different types of gases and according to these its must to be po...

Page 7: ...ses the connected equipment Check that connections are correct and that the jumper which leads to the common voltage of the relay has been carried out all the relays are voltage free Check the scheme...

Page 8: ...sible damage direct or indirect to people animals or things from product faults and from its enforced suspension of use DISPOSAL OF OLD ELECTRICAL ELECTRONIC EQUIPMENT This symbol on the product or it...

Reviews: