ComBi
line
03/04
57
3.
INSTALLATION
This appliance may only be positioned and connected by a qualified service engineer.
The following rules must be observed:
•
only suitable for indoor use
•
not suitable for use in humid areas
•
not suitable for areas with explosion hazard
3.1
Unpacking
The machine has been carefully packed to prevent damage being caused to your new appliance.
Remove the packing carefully without using sharp objects. Check if the appliance is complete.
The appliance (column) will be delivered already mounted on a console according to specifications below.
Model
CB 5/10/ 20W
Carton with accessories column:
1
•
1 wall bracket
•
1 drip tray with grid
•
1 connection hose 1,5m
•
1 descaling funnel
•
1 sachet coffee fur remover
•
1 sachet scale remover
•
1 swivel arm
•
1 manual
Please contact your dealer in case parts are missing or damaged.
3.2
Preparation for positioning
•
Place the appliance at buffet height on a firm, level base that can withstand the weight of the
machine when filled.
•
Make sure that the appliance is level and placed somewhere where it will not cause damage
should leakage occur.
•
Place the appliance in such a way that the descaler filling opening on the top of the column can be reached.
•
The water supply line (G3/4" 15 mm pipe), a discharge for the overflow connection (25 mm hose) and
the power connection must be within half a meter of where the machine is positioned.
•
The user is responsible for ensuring that these technical installation preparations are executed according
to local regulations by qualified engineers.
•
The service engineer is only permitted to connect the appliance to the prepared connection points.
WARNING
•
Water always remains in the heating system: for this reason the
appliance must not be placed in an area where the temperature
can fall below freezing point.