63
2016/01 Rev. 0.0
OptiFresh (Bean) NG 2.0
EN
Service menu continued ...
Main item
Sub-item
Item
Range Set
Description
2.13 Additional
settings
Waste
management
Cup amount
0-1000
130
After reaching the set total of brewer
movements, dispensing is disabled and
the display reads: Out of order – Waste
bin full
Hysteresis
0-100
20
After reaching the set total of brewer move-
ments minus the hysteresis is, the display
shows:
Waste bin almost full
Time-out reset
0-50 sec.
15 s
The length of time that the waste bin is al-
lowed to be removed (for emptying). When
replacing it the (internal) waste bin counter is
reset. Any display messages disappear.
Waste bin sign..
Yes/no
Yes
Turns off waste bin sensor software (bypass).
Cycle counter
xxxxx
0-99999
This Cycle counter records the number of
vends the brewer has made. Tip: This counter
can be reset after maintenance if the brewer
has been checked.
Reset c. counter
Reset counter?
Reset Cycle counter (Brewer)
Service brewer
0-50.000
40.000
When the set number of (Brewer) vends is
reached the display shows ‘
Service brewer
’.
Reset service
brewer
Reset counter?
Reset the Service brewer signal after servicing
on the brewer is performed.
Brewer open
position
6,5- 10.5 s
7,5 s
To calibrate the exact brewer open position
(piston complete down) after activatiing
brewer open/close
button.
2.16 Cleaning
management
Rinsing
rinse mandatory yes - no
nee
If rinsing mandatory is set to YES, the ma-
chine is locked if it is NOT rinsed after the set
number of cups or days.
Out of order / rinse
After the rinse programme has been comple-
ted, the machine is released again.
cups
0 - 10.000 0
days
0 - 31
1
Rinse via front
yes - no
ja
When rinsing via the front is set to YES, the
rinse programme can be activated using the
stop key on the front of the machine. Press
and hold the Stop key for 10 seconds and then
follow the instructions.
Cleaning
Cleaning man-
datory
yes - no
nee
If cleaning mandatory is set to YES, the
machine is locked if it is NOT cleaned after the
set number of cups or days.
‘
Out of order / clean
After the cleaning programme has been com-
pleted, the machine is released again.
cups
0 - 10.000 0
days
0 - 31
7
Change brewer
filter
change man-
datory
yes - no
nee
If change mandatory is set to YES, the ma-
chine is locked if the brewer filter was NOT e
changed after the set number of cups or days.
After the change brewer filter programme has
been completed, the machine is released
again.
cups
0 - 10.000 10.000
days
0-31
0