background image

60

06/2011 Rev. 7.4        

M o d e l   2 0 0 9

06/2011 Rev. 7.4

61

M o d e l   2 0 0 9

PIN Code Table

 No.

Pincode

No.

Pincode

1

3

4

2

4

2

11

1

3

3

3

2

2

3

1

4

3

4

12

1

2

4

1

3

3

4

1

3

4

3

13

4

3

1

2

1

4

4

3

2

3

2

14

1

1

1

4

2

5

2

3

3

4

1

15

2

1

2

1

1

6

4

2

1

3

1

16

1

2

2

3

3

7

2

4

2

4

4

17

3

4

1

4

4

8

2

3

2

4

1

18

4

1

4

3

3

9

2

4

3

2

3

19

3

1

2

4

1

Table 1

10

3

1

3

3

2

20

2

2

3

2

4

Water Hardness Table 

Water

Quality

Hardness

Limescale

Indicator ...cups

°D

°F

°C

mmol/l

mgCaCo3/l

Very hard

18-30

32-55

11-18

3,2-5,3

321- 536

5000

Hard

12-18

22-32

7-18

2,2-3,2

214-321

8500

Average

8-12

15-22

5-7

1,4-2,2

268-214

12.500*

Soft

4-8

7-15

2-5

0,7-1,4

72-268

20.500

Table 2

Very soft

0-4

0-7

0-2

0- 0,7

0-72

0 = off

3. RECIPE 

SETTINGS

3.1 Quick recipe

First of all we would like to remind you that the 

cup volume

 (ml) and 

strength

 (%) can easily be set in 

the service menu 

2.1 Quick recipe

 (page 52 of this document).

The operator of the device (end user) also has access to this quick recipe, which is found under 
section 1.4 Quick recipe (see user manual). As supplier of the device, you can remove the quick recipe 
from the operator menu if desired. Go to 

2.4 Settings / 2.4.9 I/0 Quick recipe

 via the service menu 

and change 

Yes

 into 

No

.

3.2 Model code system

The OptiVend models have the following standard canister con gurations (table 3):

Table 3

Model

code

Canister

1

2

3

4

OptiVend 1

1V1A

Coffee

-

-

-

OptiVend 2

1V2A

Coffee

Chocolate

-

-

OptiVend 3

1V3A

Coffee

-

Topping

Chocolate

OptiVend 4

1V4A

Coffee

Sugar

Topping

Chocolate

OptiVend 1 TS/TL

1V5A

-

-

Coffee

-

OptiVend 2 TS 

1

1V6A

Coffee

-

Chocolate

-

OptiVend 3 TS

1V7A

Coffee

-

Topping

Chocolate

OptiVend 4 TS

1V8A

Coffee

Sugar

Topping

Chocolate

OptiVend HS

1V9A

Coffee

-

Coffee

-

OptiVend Choco

1VAA

Chocolate

-

-

-

OptiVend HS DUO

1VBA

Coffee

-

Coffee

-

OptiVend HS DUO capp 

1

1VCA

Coffee

Topping

Coffee

Topping

OptiVend 3 Sugar 

2

1VDA

Coffee

-

Topping

Sugar

OptiVend 3 TS Sugar 

2

1VEA

Coffee

-

Topping

Sugar

1

 Special model, only available on request

2

standard model with different canister confi guration (from software V1.02 June 2009)

 

3.3 Button settings

The standard of programmed recipes (table 4, 5 and 6) can easily be transferred over the 12 recipe 
buttons. See service menu 

2.2 Button settings

 (page 52).

The optional recipes table are already contained in the software and can easily be programmed under 
one recipe button. 

Summary of Contents for OPTIVEND 2009

Page 1: ...NL GB D F Service boek Service book Servicehandbuch Manuel de service maintenance M o d e l 2 0 0 9...

Page 2: ...ater dispensing 48 1 4 Cold water dispensing optional 48 1 5 Ingredients and mixer system 48 1 6 Evaporation extractor system 49 1 7 Solid state relay SSR 49 1 8 Steam thermostat 49 2 MENU STRUCTURE 5...

Page 3: ...ve this document with the user after installation and to change the standard factory PIN code All sections and paragraphs are numbered The various gures referred to in the text can be found in the gur...

Page 4: ...l amount of rinsing water is released shortly after dispensing to rinse away any ingredient residue 1 4 Cold water dispensing optional OptiVend has a built in cold water option special base cabinet wi...

Page 5: ...ll automatically revert to standby mode Sat On 00 00 Off 00 00 Sun On 00 00 Off 00 00 1 3 Recipe counters Recipe 1 Recipe 10 Total Off 00 00 Total counter for recipe 1 free paid jugs Free Cups Number...

Page 6: ...bination with a hot cold water recipe button Drip time 0 10 sec 2 sec The length of time that the product continues to run from the brewer or mixer After this time has elapsed a new drink selection ca...

Page 7: ...V HS DUO Hysteresis 2 10 C 2 C Temperature drop after which boiler must reheat Output block 70 80 C 78 C Boiler temperature disables dispens ing Display Out of order boiler heating Output release 70 8...

Page 8: ...s menu item to the operator menu I 0 Quick recipe Yes no Yes Add Quick recipe menu item to the operator menu Drip tray sign 1 Yes no Yes Turns off drip tray sensor software Demo modus 3 Yes no No This...

Page 9: ...the new model settings will be activated When you con rm this setting all loaded factory settings and changed programmed values will be lost After loading defaults the PIN code reverts to 2 2 2 2 2 a...

Page 10: ...remove the quick recipe from the operator menu if desired Go to 2 4 Settings 2 4 9 I 0 Quick recipe via the service menu and change Yes into No 3 2 Model code system The OptiVend models have the foll...

Page 11: ...e Sugar Espresso Sugar Soup Soup Soup only if the necessary ingredient s are available in the canisters Tea Tea Tea Table 5 OptiVend 1 TS TL OptiVend 2 TS OptiVend 3 TS Hot Cold OptiVend 4 TS Hot Cold...

Page 12: ...sters 1 Coffee Coffee Coffee Coffee Coffee 2 Topping Chocolate 3 Coffee Coffee Coffee Topping Topping 4 Topping Chocolate Sugar Sugar Button 3 1 3 1 3 4 1 2 1 3 4 1 3 4 Standard recipes 1 Coffee Black...

Page 13: ...1 1 OptiVend Choco Unit 1 DV 1 Mixer 1 1 DV 4 Hot water OptiVend 1 Unit 1 DV 1 Mixer 1 DV 4 Hot water 1 2 OptiVend 2 DV 2 Mixer 2 DV 4 Hot water 3 Unit 1 Unit 2 OptiVend 1 TS 1 TL DV 1 DV 2 Mixer 1 M...

Page 14: ...allation set a parameter for the device to be serviced See Service Menu item 2 8 Descale lter Use the table below to set the correct service parameter Service parameter reached The dispensed drinks ar...

Page 15: ...e Table 8 WARNING Do not leave the device during maintenance work When descaling always follow the instructions for the descaler used It is advisable to wear safety goggles and protective gloves when...

Page 16: ...clean water Repeat instruction 10 one more time to rinse the reservoir completely free of acid 13 Turn on the device again the reservoir will re ll with clean water Allow the water reservoir to heat u...

Page 17: ...INGREDIENT MOTORS MIXERS 4 3 FAN INLET OUTPUTS G13 MDB RS232 COMMUNICATION POWER SUPPLY MICROCONTROLLER J15 J6 J2 USB J4 2 1 TEMP1 2 1 4 3 24V DC KEY DISPLAY INPUTS J12 J7 J16 J1 F1 BATT F6 3AT 1 2 3...

Page 18: ...Take care to rotate in the right direction Shared 24 DC red wire on red spot on Mixer and Ingredients Motor 15 16 Mixer 2 Violet 13 14 Mixer 3 11 12 Ingredient Motor 1 Brown 9 10 Ingredient Motor 2 G...

Page 19: ...f order Boiler heating The boiler temperature is temporarily too low because too much water has been used Once the temperature is restored the message automatically disappears and the drink selection...

Page 20: ...unication be tween machine and MDB payment system Check the connection between the machine and MDB payment system Out of order E18 mixer FET error Mixer motor output remains active Mixer motor output...

Page 21: ...epting Euros and Tokens Carry out section 8 1 3 and 8 1 4 beforehand Open the service menu Set a price using menu 2 2 Button settings Button 1 12 Price e g 0 50 The recipe buttons are activated after...

Page 22: ...coin changer suitable for euros 0 05 2 00 Other currencies are available on request The coin changer has 6 coin tubes 0 05 2x 0 10 0 20 0 50 1 00 1 Return button 2 Coin insert 3 Lock 4 Change 8 2 1 T...

Page 23: ...eadof ce Dr A F Philipsweg 47 P O Box 71 9400 AB Assen The Netherlands Tel no 31 0 592 376376 Fax no 31 0 592 341751 E mail info animo nl Internet http www animo eu Rev 7 4 06 2011 Art nr 09897 M o d...