background image

80

06/2011 Rev. 7.4        

M o d e l   2 0 0 9

06/2011 Rev. 7.4

81

M o d e l   2 0 0 9

Display

Possible cause

Action

Out of order 
E10 Valve error

Valve exit overload (power too 
high). Control unit has switched off 
the exit.

Check valves and wiring for leakage. 
Switch the device off and on again.

Out of order 
E11 Ingr. m error

Ingredient motor stuck. Ingredient 
motor exit overload (power too 
high). Control unit has switched off 
the exits.

Check the driving motor function in service 
menu 

2.7 Hardware test

. Empty the 

Canister(s) and clean thoroughly. See 
User manual section 

8.9 Cleaning the 

canister(s)

. Switch the device off and on 

again.

Out of order 
E12 Fan error

Fan exit overload (power too 
high). Control unit has switched off 
the exits.

Check the ventilator and wiring for leakage. 
Switch the device off and on again.

Out of order 
E13 Mixer error

Mixer exit group overload (power 
too high). (power too high). Con-
trol unit has switched off the exits.

Carry out the inspection actions as 
described for E7, E8 and E9. Switch the 
device off and on again.

Out of order 
E14 Output err.

Ingredient motor and ventilator 
exit group overload (power too 
high). Control unit has switched off 
the exits.

Carry out the inspection actions as
described for E11 and E12. Switch the 
device off and on again.

Valve exit group overload 
(power too high). Control unit has 
switched off the exits.

Carry out the inspection actions as
described for E10. Switch the device off 
and on again.

Out of order 
E16 Level error

Electrode error; Max. and Min. 
Electrode both suddenly detect no 
water level. Inlet valve shuts. 

Make sure if the boiler does not leaks.
Check the water pressure, turn the water 
supply tap completely open and check the 
connection tube for any kinks. Switch the 
device off and on again.

Out of order 
E17 MDB error

There is no communication be-
tween machine and MDB payment 
system

Check the connection between the
machine and MDB payment system.

Out of order 
E18 mixer FET error

Mixer motor output remains active.

Mixer motor output (FET) defective. 
Replace PC board.

Out of order
E19 Output FET error

Ingredient motor / valve / ventilator 
output remains active.

Ingredient motor / valve / ventilator output 
(FET) defective. Replace PC board.

Out of order 
E20 Software error

Software fault

Reset machine.
Load defaults.
Install new software.

Out of order 
E21 Boiler timeout

Heating element heats for max. 
8 minutes. If boiler still has not  
reached its temperature this error 
occurs. Dry boil protection and / or 
steam thermostat is enabled.

Reset the steam thermostat, 
see CHAPTER 1.8
Check the logmenu. If a E6 boiler temp. the 
boiler has boiled to long. Check the NTC 
sensor and wiring / connection

8. PAYMENT SYSTEMS

8.1 Coin mechanism (optional)

The OptiVend is available with an optional coin 
mechanism suitable for euros (€0.05 - €2.00). Other 
currencies are available on request.

The coin mechanism can also easily be programmed to 
accept tokens.

It is also possible to have an existing device  tted 
with the coin mechanism. The right-hand side panel is 
replaced by a wider side panel, which houses the coin 
mechanism and slot ( g. 17).

1. Coin insert

2. Return button

3. Return slot

4. Money drawer

5.  Door lock (also locks the money drawer)

8.1.1 Standard con guration

Fig. 18 shows the standard con guration of the DIL 
switches, S1-10 ON

The coin mechanism is connected to the device with a 
connector (Fig. 18A).

 

8.1.2 Rejecting coins

If desired, certain types of euro coins can be rejected by 
using DIL-Switch block S1 + S2 ( g. 18).

Coin

DIL   +

DIL    

€ 0,05

S1-1

S1-7

€ 0,10

S1-2

S1-8

€ 0,20

S1-3

S2-1

€ 0,50

S1-4

S2-2

€ 1,00

S1-5

S2-3

€ 2,00

S1-6

S2-4

Token 607

   -

S2-5

Token Eagle

   -

S2-6

Token new

   -

S2-7

Token new

   -

S2-8

ON = rejected / OFF = accepted

Example: Reject €1 and €2 euro coins ( g. 19)

  S1-5,   S2-3 -> ON (€ 1,00 rejected)

  S1-6,   S2-4 -> ON (€ 2,00 rejected)

S1

S2

A

S1

S2

Fig. 17

Fig. 18

Fig. 19

Summary of Contents for OPTIVEND 2009

Page 1: ...NL GB D F Service boek Service book Servicehandbuch Manuel de service maintenance M o d e l 2 0 0 9...

Page 2: ...ater dispensing 48 1 4 Cold water dispensing optional 48 1 5 Ingredients and mixer system 48 1 6 Evaporation extractor system 49 1 7 Solid state relay SSR 49 1 8 Steam thermostat 49 2 MENU STRUCTURE 5...

Page 3: ...ve this document with the user after installation and to change the standard factory PIN code All sections and paragraphs are numbered The various gures referred to in the text can be found in the gur...

Page 4: ...l amount of rinsing water is released shortly after dispensing to rinse away any ingredient residue 1 4 Cold water dispensing optional OptiVend has a built in cold water option special base cabinet wi...

Page 5: ...ll automatically revert to standby mode Sat On 00 00 Off 00 00 Sun On 00 00 Off 00 00 1 3 Recipe counters Recipe 1 Recipe 10 Total Off 00 00 Total counter for recipe 1 free paid jugs Free Cups Number...

Page 6: ...bination with a hot cold water recipe button Drip time 0 10 sec 2 sec The length of time that the product continues to run from the brewer or mixer After this time has elapsed a new drink selection ca...

Page 7: ...V HS DUO Hysteresis 2 10 C 2 C Temperature drop after which boiler must reheat Output block 70 80 C 78 C Boiler temperature disables dispens ing Display Out of order boiler heating Output release 70 8...

Page 8: ...s menu item to the operator menu I 0 Quick recipe Yes no Yes Add Quick recipe menu item to the operator menu Drip tray sign 1 Yes no Yes Turns off drip tray sensor software Demo modus 3 Yes no No This...

Page 9: ...the new model settings will be activated When you con rm this setting all loaded factory settings and changed programmed values will be lost After loading defaults the PIN code reverts to 2 2 2 2 2 a...

Page 10: ...remove the quick recipe from the operator menu if desired Go to 2 4 Settings 2 4 9 I 0 Quick recipe via the service menu and change Yes into No 3 2 Model code system The OptiVend models have the foll...

Page 11: ...e Sugar Espresso Sugar Soup Soup Soup only if the necessary ingredient s are available in the canisters Tea Tea Tea Table 5 OptiVend 1 TS TL OptiVend 2 TS OptiVend 3 TS Hot Cold OptiVend 4 TS Hot Cold...

Page 12: ...sters 1 Coffee Coffee Coffee Coffee Coffee 2 Topping Chocolate 3 Coffee Coffee Coffee Topping Topping 4 Topping Chocolate Sugar Sugar Button 3 1 3 1 3 4 1 2 1 3 4 1 3 4 Standard recipes 1 Coffee Black...

Page 13: ...1 1 OptiVend Choco Unit 1 DV 1 Mixer 1 1 DV 4 Hot water OptiVend 1 Unit 1 DV 1 Mixer 1 DV 4 Hot water 1 2 OptiVend 2 DV 2 Mixer 2 DV 4 Hot water 3 Unit 1 Unit 2 OptiVend 1 TS 1 TL DV 1 DV 2 Mixer 1 M...

Page 14: ...allation set a parameter for the device to be serviced See Service Menu item 2 8 Descale lter Use the table below to set the correct service parameter Service parameter reached The dispensed drinks ar...

Page 15: ...e Table 8 WARNING Do not leave the device during maintenance work When descaling always follow the instructions for the descaler used It is advisable to wear safety goggles and protective gloves when...

Page 16: ...clean water Repeat instruction 10 one more time to rinse the reservoir completely free of acid 13 Turn on the device again the reservoir will re ll with clean water Allow the water reservoir to heat u...

Page 17: ...INGREDIENT MOTORS MIXERS 4 3 FAN INLET OUTPUTS G13 MDB RS232 COMMUNICATION POWER SUPPLY MICROCONTROLLER J15 J6 J2 USB J4 2 1 TEMP1 2 1 4 3 24V DC KEY DISPLAY INPUTS J12 J7 J16 J1 F1 BATT F6 3AT 1 2 3...

Page 18: ...Take care to rotate in the right direction Shared 24 DC red wire on red spot on Mixer and Ingredients Motor 15 16 Mixer 2 Violet 13 14 Mixer 3 11 12 Ingredient Motor 1 Brown 9 10 Ingredient Motor 2 G...

Page 19: ...f order Boiler heating The boiler temperature is temporarily too low because too much water has been used Once the temperature is restored the message automatically disappears and the drink selection...

Page 20: ...unication be tween machine and MDB payment system Check the connection between the machine and MDB payment system Out of order E18 mixer FET error Mixer motor output remains active Mixer motor output...

Page 21: ...epting Euros and Tokens Carry out section 8 1 3 and 8 1 4 beforehand Open the service menu Set a price using menu 2 2 Button settings Button 1 12 Price e g 0 50 The recipe buttons are activated after...

Page 22: ...coin changer suitable for euros 0 05 2 00 Other currencies are available on request The coin changer has 6 coin tubes 0 05 2x 0 10 0 20 0 50 1 00 1 Return button 2 Coin insert 3 Lock 4 Change 8 2 1 T...

Page 23: ...eadof ce Dr A F Philipsweg 47 P O Box 71 9400 AB Assen The Netherlands Tel no 31 0 592 376376 Fax no 31 0 592 341751 E mail info animo nl Internet http www animo eu Rev 7 4 06 2011 Art nr 09897 M o d...