3. INSTALLATION
Before installing the machine, carry out the
following steps:
•
Position the machine on a firm and even
surface so that it can be connected to the
electricity and water supplies.
•
The TA202 W with automatic filling should
be positioned near a manually-operated
water tap. The water supply hose is 1.25
metres long.
•
When positioning the machine, bear in
mind that it is equipped with an overflow
device.
The machine should be connected as
demonstrated in the diagrams shown below,
depending on the machine’s electrical fittings.
•
(Fig. 4) For 220V -240V 3 live
(4 core electric cable).
•
(Fig. 5) For 380V-415V 3 live/neutral
(5 core electric cable).
The following points should be observed when
wiring a new plug:
•
The green/yellow-coloured wire (“EARTH”)
should be connected to the terminal which is
either marked with the letter “E”, the “earth”
symbol ( ), or coloured green or green/
yellow.
•
The blue-coloured wire (“NEUTRAL”)
should be connected to the terminal which
is either marked with the letter “N” or
coloured black.
•
The brown-coloured wire (“LIVE”) should be
connected to the terminal which is either
marked with the letter “L” or coloured brown.
IMPORTANT !
The four or five core mains cable (fig. 4/ fig. 5)
has the following wiring code:
Green/Yellow
-
Earth
Blue
-
Neutral
Brown
-
Live
Black
-
Live
Animo
3
09/99
TA 202 W
fig. 4
Green/Yellow - Earth
(E)
Brown
- Live
(L1)
Black
- Live
(L2)
Black
- Live
(L3)
fig. 5
Green/Yellow - Earth
(E)
Blue
- Neutral (N)
Brown
- Live 1
(L1)
Black
- Live 2
(L2)
Black
- Live 3
(L3)