background image

mark the wall or floor through the holes in the safe. The safe should be fixed as shown in following diagram. Ensure
no electrical cabling, gas or water pipes are hidden where you intend to drill. Using a 12 mm masonry drill bit, drill at
the marked locations. Insert the split tubes together with bolts, washers and wedge nuts into each hole. Pretighten
the bolts to fix the wedge nuts in the tubes. Then remove the bolts with washers. Locate the safe, add the washers and
tighten the bolts.

To register the fingerprint

Press the red button 

while the door is open, you will hear several beeps and the fingerprint scanner 

 will light up

(3) 

(5)

red. Immediately place your finger and keep it on the scanner 

 until two short beeps are heard. Then the green

(5)

LED 

will light up with a long beep. This indicates the fingerprint is successfully registered. otherwise both red 

(4)

(3)

 

and green LEDs 

will blink with short beeps. Repeat above steps to register more ditferent fingerprints.

(4)

 

Note: Maximum 20 fingerprints can be registered.
Note: In order to improve the fingerprint identification, users may refer to the following advice:
     • Keep the fingerprint scanner clean.
     • It is better that each user registers 2-3 fingerprints.
     • It is recommended for women and children to register with either a thumb or a middlefinger.
     • When registering fingerprint, press gently with even power.

To set and change the user code

Press and hold the number key '1' until the green LED 

is on. Input the original code (the default code is

) and

(4)

1234

 

 

press the ON/OFF-Button 

 to confirm. After hearing a long beep, input your new user code (4 to 8 numbers) and

(6)

press the ON/OFF-Button 

 .Then input the new code again and press the ON/OFF Button 

 to reconfirm. When a

(6)

(0)

long beep is heard, the user code is successfully changed. If both red and green LEDs 

keep blinking with beeps,

(4)

 

it means wrong code is entered. To change the code, repeat above steps. Note: Each touch of the keypad will cause
the green LED 

to flash and a short been to be emitted.

(4)

 

To open the safe door using the fingerprint

Press the ON/OFF-Button 

and the fingerprint scanner 

will light up red. Immediame place your finger and keep

(6)

(5)

 

 

it on the scanner 

until the green LED 

 is on and a long beep is heard. Turn the knob 

 clockwise and pull to open

(5)

(4) 

(1)

 

the safe. If both red 

and green LEDs 

keep blinking with short beeps. it means no registered fingerprint is detected.

(3)

(4)

 

 

To open the safe door using user code

Input your user code (4 to 8 numbers) and press the ON/OFF-Button 

to confirm. After hearing a long beep, the green

(6)

 

light 

 will be on. Turn the knob clockwise and pull to open the safe.

(4)

Resetting the safe

Press and hold the red button 

while the door is open. After a short beep, the green LED 

will starlblinking for

(3)

(4)

 

 

about 10 seconds and stop with a long beep. Release the red button 

 then as the safe has been reset to the factory 

(8)

default setting. All registered fingerprints have been deleted and the user code has been set back to the default 
code

 

1234

.

How to use your override key

If you cannot open the safe using either fingerprint or code, push on the middle of the ovenide keyhole cover 

to

(7)

 

slide it off. Then locate the keyhole to insert the override key and turn it anticlockwise. At the same time, turn the knob
clockwise and open the safe door. Do not keep the override key in the safe.

Producer:
ANKARO GmbH
Hauptstraße 6
D-14979 Großbeeren

Summary of Contents for ANK EZ I

Page 1: ...en Sie ausschließlich Alkali Batterien Um die Batterien einzulegen öffnen Sie das Batteriefach auf der Innenseite der Tresortür und legen die 9 Batterien wie gekennzeichnet mit der richtigen Polarisation in das Batteriefach ein 9 Auswechseln der Batterien Wenn die rote LED leuchten tauschen sie SOFORT die Batterien aus Stellen Sie sicher dass die Batterien richtig 3 herum eingelegt werden Mischen ...

Page 2: ...stätigung Geben Sie den 6 neuen Code erneut ein und drücken Sie die EIN Aus Taste zur Bestätigung Wenn Sie jetzt einen langen 6 Piepton hören war die Eingabe erfolgreich Sollte die rote und grüne LED aufleuchten war die Eingabe 3 4 nicht erfolgreich Um den Code zu verändern wiederholen Sie die eben genannten Schritte Beachten Sie dass bei jeder Eingabe die grüne LED kurz aufleuchtet und Sie einen ...

Page 3: ...ht is on change the batteries immediately Make sure that the batteries are installed correctly Please have a test before you close the safe door Note Do not use new or old batteries together Installing the safe It is recommended removing the shelf before installing the safe To reduce the risk of theft the safe must be affixed to the floor or wall For your convenience there are holes in the bottom ...

Page 4: ... to 8 numbers and 6 press the ON OFF Button Then input the new code again and press the ON OFF Button to reconfirm When a 6 0 long beep is heard the user code is successfully changed If both red and green LEDs keep blinking with beeps 4 it means wrong code is entered To change the code repeat above steps Note Each touch of the keypad will cause the green LED to flash and a short been to be emitted...