background image

 AV 80/40X - AV 90/50X · User’s guide 

 

 

- 3 -            AV 80/40X - AV 90/50X             Version_en_1.0           Ankaro 

 
Configuration of pre-amplifiers feeding 
The configuration of pre-amplifiers feeding is made though jumpers, depending on the model it will feed one or two UHF 
inputs. 
 

Models 

AV 80/401 

AV 80/402 

AV 90/501 

AV 90/502 

UHF inputs with  

pre-amplifier feeding 

1 2 1 2 

 

Power pass 

ON 

OFF 

Jumper configuration 

 

 

 
The AV 90/50X models give the possibility of feeding the pre-amplifier in 12VDC or in 24VDC, while the AV 80/40X 
models can only feed in12VDC. 
 

Feeding  

12VDC 

24VDC 

Jumpers configuration 

AV 90/50X 

 

 

 
 
Installation 
The equipment is provided with a wall support with wedges and screws included. 
The steps to make a correct installation are the followings: 

-

 

Bring down the fastening device. The equipment will be now loosed and it will be possible to separate the support 
from the equipment. 

-

 

Fix the support to the wall with the wedged and screws provided. 

-

 

Introduce the equipment again in the wall support once it is installed. 

-

 

Bring up the fastening device to adjust the equipment to the support. 

 

 

 

 
 
AV 80/40X - AV 90/50X 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
1-2  

UHF IN: Terrestrial signal input UHF 470-862 MHz  

3-4 

VHF IN: Terrestrial signal input VHF 47-230 MHz  

TEST OUTPUT: Test output (-30dB) (only AV 90/50X) 

OUT: Terrestrial signal output UHF+VHF 47-862MHz 

AC IN: Feeding cable ( 230V AC, 50Hz ) 

 

1       2                3       4       

  5       6 

  7 

Summary of Contents for AV 80

Page 1: ... wet hands Also disconnect always the device before handling the connections 14 Never put any heavy object over the device as it could get damaged 15 If the equipment is going to remain some time without use it is recommendable to disconnect it from the electrical net 16 The repairmen and the maintenance of the equipment must be done by TV and radio specialist technicians 1 2 Box content AV 80 40X...

Page 2: ... and for VHF is 18dB The maximum output level of these models is 114dBuV AV 90 50X Main Features The gain in AV 90 50X models in UHF is 56dB and 54 dB depending on the model In VHF the gain is 44dB in both models The regulation is 20dB for UHF and VHF in all the models The maximum output level of these models is 125dBuV These models are provided with a Test output of 30dB AV 80 401 AV 80 402 AV 90...

Page 3: ...90 50X Installation The equipment is provided with a wall support with wedges and screws included The steps to make a correct installation are the followings Bring down the fastening device The equipment will be now loosed and it will be possible to separate the support from the equipment Fix the support to the wall with the wedged and screws provided Introduce the equipment again in the wall supp...

Page 4: ...8300 B3 DAB Filter Mod DABF Code 08300 DAB BIV Filter Mod B4F Code 08300 B4 BV Filter Mod B5F Code 08300 B5 Example of installation Example of an installation of a 5 floors building with two dwellings per floor The UHF VHF signals are distributed in each outlet The amplifier allows regulating the signal and configuring the different bands of each input through plug in filters this way we can get t...

Page 5: ...HF1 VHF2 Gain 30 18 dB 44 dB UHF Regulation 15 dB 20 dB VHF Regulation 18 dB 20 dB Maximum output level 114 dBµV 125 dBµV Pre amplifiers feeding UHF 12 V 12 24 V Protection grade IP 40 IP 65 Consumption 230V 50Hz 2 2W 230V 50Hz 14W Measures 175 x 50 x 98 mm 230 x 140 x 60 mm Chapter 3 Conformity declaration CONFORMITY DECLARATION WE ANKARO DECLARE THAT THE PRODUCTS AV 80 401 AV 80 402 AV 90 501 AN...