AV 80/40X - AV 90/50X · User’s guide
- 3 - AV 80/40X - AV 90/50X Version_en_1.0 Ankaro
Configuration of pre-amplifiers feeding
The configuration of pre-amplifiers feeding is made though jumpers, depending on the model it will feed one or two UHF
inputs.
Models
AV 80/401
AV 80/402
AV 90/501
AV 90/502
UHF inputs with
pre-amplifier feeding
1 2 1 2
Power pass
ON
OFF
Jumper configuration
The AV 90/50X models give the possibility of feeding the pre-amplifier in 12VDC or in 24VDC, while the AV 80/40X
models can only feed in12VDC.
Feeding
12VDC
24VDC
Jumpers configuration
AV 90/50X
Installation
The equipment is provided with a wall support with wedges and screws included.
The steps to make a correct installation are the followings:
-
Bring down the fastening device. The equipment will be now loosed and it will be possible to separate the support
from the equipment.
-
Fix the support to the wall with the wedged and screws provided.
-
Introduce the equipment again in the wall support once it is installed.
-
Bring up the fastening device to adjust the equipment to the support.
AV 80/40X - AV 90/50X
1-2
UHF IN: Terrestrial signal input UHF 470-862 MHz
3-4
VHF IN: Terrestrial signal input VHF 47-230 MHz
5
TEST OUTPUT: Test output (-30dB) (only AV 90/50X)
6
OUT: Terrestrial signal output UHF+VHF 47-862MHz
7
AC IN: Feeding cable ( 230V AC, 50Hz )
1 2 3 4
5 6
7