background image

 

                   

                                                                                                                                                                                                         

 

 
 
 
 

1)

 

Whenever changing a bit, make certain the Forward / Reverse Switch is in the “ OFF “ position and tool is unplugged. 

2)

  To avoid damaging the housing of screwdriver, do not allow chemicals get in touch with housing of screwdriver. Ex.: 

Acetone, benzene, thinner, trichloroethylene ketone, and other similar chemicals.

 

3)

  Use screwdriver carefully, do not drop or abuse. It would be better to use with the spring balancer. If without spring 

balancer, you can place the screwdriver in the suspension rack.

 

4)

  Assemble / disassemble bits : Only use fingers pull up the bit sleeve to release bits. ; Place back the bit sleeve to lock 

the bit holder.

 

Attenti

on : Make sure the power is off, or the Forward / Reverse switch stays at “OFF” position when assemble or 

disassemble bits. 

5)

  Connect the plug to the socket. Attention : It will cause an electric shock if the plug or the hand is wet. 

6)

  You can adjust the torque by the torque adjusting ring. The number on the scale is not equal to the real torque, please 

refer to our torque range chart, or test the torque by our torque meter. 

Attention : Do not adjust the torque setting higher than 8 on the torque scale. 

7)

  MY5-TR0309 Series screwdriver : When fasten a screw, please point the bit to left, move down the Forward / 

Reverse   
switch to the bottom. (If the screw is reversed-thread screw, move up the Forward / Reverse switch to the top.)   
Point at the place of the bit and the screw, press the trigger to start; When

torque reaches user’s setting, the clutch will 

shut out automatically, the power will shut off and the motor breaks immediately, the screwdriver stop running. 

8)

  Trigger Start Type screwdriver : When loosen a fastene

d screw, please set Forward / Reverse switch to “Reverse”. 

          (If the screw is reversed-thread screw, please set Forward / Reve

rse switch to “Forward”.) 

          Follow the above operation, after loosening the screw, release the trigger to stop. 
          Push St

art Type screwdriver : When loosen a fastened screw, please set Forward / Reverse switch to “Reverse” 

          (If the screw is reversed-thread scre

w, please set Forward / Reverse switch to “Forward”.) 

          Follow the above operation, after loosening the screw, stop pushing the screwdriver to stop. 

9)

  Operation frequency: The original setting of the frequency is 1 sec on / 3 sec off. The number of screw fastened is 

about 15 pcs. Over frequently using makes the motor overheated and damage to screwdriver.   

          Enough heat-dissipation is good for screwdriver. 

 
 
 
 
 

 

10)

  Do not use this screwdriver to fasten wooden screws. 

11)

  Do not operate the Forward / Reverse switch when the motor is running. 

12)

  Whenever a screwdriver is not being used, move 

the Forward / Reverse switch to the “middle” position and unplug 

the screwdriver. 

13)

  Keep staying aware. 

          Pay attention on your work, check safety measures and every part is workable before using screwdrivers, to make   
          sure screwdrivers can work under original design function. 

14)

  Use cable for the external counter and I/O box is shield cable for avoidance of electrical interference 

    Use Anti-interference lines. 

15)

  When replacing the control PCB or clutch assembly of Electric Screwdriver, the screwdriver is required to 

    do calibration with MY-TR.

 

 
 
 
 

● Do not drop or abuse the tool.   
● Whenever a tool is not being used, position the Power Switch to the “OFF” position and unplug the power cord. 

 

Slow speed (rpm)  operation frequency

 

Slow speed (rpm)

 

operation frequency

 

Slow speed (rpm)

 

operation frequency

 

900 

1.0 ON 3.0 OFF 

600 

1.0 ON 3.0 OFF 

300

 

2.0 ON 5.0 OFF 

850

 

1.0 ON 3.0 OFF 

550

 

2.0 ON 5.0 OFF 

250

 

2.0 ON 5.0 OFF 

800

 

1.0 ON 3.0 OFF 

500

 

2.0 ON 5.0 OFF 

200

 

2.0 ON 5.0 OFF 

750 

1.0 ON 3.0 OFF 

450

 

2.0 ON 5.0 OFF 

150

 

2.0 ON 5.0 OFF 

700 

1.0 ON 3.0 OFF 

400

 

2.0 ON 5.0 OFF 

100

 

2.0 ON 5.0 OFF 

650 

1.0 ON 3.0 OFF 

350

 

2.0 ON 5.0 OFF 

 

 

Operations Cautions 

CAUTION 

Slow speed Duty Cycle Conversion (for reference) 
Based on 1000 rpm, 1 second ON/3 seconds OFF. For example, the duty cycle for 350rpm,1000-350=650

 

650/1000%=65% 
ON= 1*1.65= 1.65

OFF =3*1.65 =4.95 (rounded value) =2 seconds ON / 5 seconds OFF 

This tool is intended for a duty cycle of 2.0 sec on, 5.0 sec off. 

Summary of Contents for MYTORQ MY5-TR0212L

Page 1: ...NTENANCE MANUAL DC TYPE Automatic Non Carbon Brush Series ANLIDAR INDUSTRIAL CO LTD http www anlidar com Y2F160A 3E 004 MY5 TR0212L MY5 TR0319L MY5 TR0212LF MY5 TR0317LF MY5 TR0212P MY5 TR0319P MY5 TR0212PF MY5 TR0317PF ...

Page 2: ...tion enclosed Read all these instructions before placing tool in service or operation this tool and save these instructions It is the responsibility of the employer to place the information in this manual into the hands of the operator Failure to observe the following warnings could result in injury When using electric tools Basic safety precautions should always be followed to reduce the risk of ...

Page 3: ...and use common sense when operating a power tool Do not use power tool while you are tired or under the influence of drugs alcohol or medication A moment of inattention while operating power tools may result in serious personal injury b Use safety equipment Always wear eye protection Safety equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate condit...

Page 4: ...ng edges are less likely to bind and are easier to control g Use the power tools accessories and tool bits etc in accordance with these instructions and in the manner intended for the particular type of power tool taking into account the working conditions and the work to be performed Use of the power tool for operations different from intended could result in a hazardous situation 5 SERVICE a Hav...

Page 5: ...t important task a user Periodically depends on the working condition and circumstance for maintaining a good function the user has to check the grounding condition every 3 6 months by an electric meter and following simple steps Set the Ohm meter to level R 100 Ohm Touching 2 test rods together and reset the meter to 0 Using the Red rod to touch the Grounding wire on the Plug of controller s cord...

Page 6: ...astened screw please set Forward Reverse switch to Reverse If the screw is reversed thread screw please set Forward Reverse switch to Forward Follow the above operation after loosening the screw stop pushing the screwdriver to stop 9 Operation frequency The original setting of the frequency is 1 sec on 3 sec off The number of screw fastened is about 15 pcs Over frequently using makes the motor ove...

Page 7: ...t rotation and set up the switch to Lo for slowest rotation It s possible that the uncompleted shut off occurs when the switch is setup to Lo and the presetting torque is more than 50 of torque range Please refer to the following table Maintenance and Inspection 1 The screwdriver must be operated in top condition one day working hour must be not more than eight hours 2 Please note don t let the mo...

Page 8: ... center 3 Anlidar is not responsible for customer modification of tools for applications on which Anlidar was not consulted 4 Repairs should be made only by authorized trained personnel Consult your nearest MYTORQ authorized service center 5 It is the responsibility of the employer to place the information in this manual into the hands of the operator DO NOT ATTEMPT TO REPAIR THIS ELECTRIC SCREWDR...

Page 9: ...3 0 2 3 3 5 1 6 3 0 1 6 3 0 Tapping screw 1 6 2 6 2 3 3 0 1 6 2 6 1 6 2 6 1 6 2 6 2 3 3 0 1 6 2 6 1 6 2 6 Weight g 520 Length mm 245 Model of Torque Locker KC 6C KC 6S Power controller MYP32 300N Display Box MY TR Model of Screwdriver Holder KH 4 KC KH 2 Bit Type HEX 5mm HEX 6 35mm Ø 4mm Ø 5mm 1N m 10 2Kgf cm 1N m 8 85Lbf in 1 BIT Type No 00 Bit use in dia 1 3 1 8mm screw No 0 Bit use in dia 1 8 2...

Page 10: ...ch or the like is available as one of torque control methods however note that the measured values by the return torque method generally appear in 10 30 lower than the actually clamping torque 7 The torque checker measures the torque of screwdriver The clamping torque of screw itself is different from the clamped conditions Understand the correlation between clamping torque values and the torque c...

Reviews: