10
Program
setting
Screw List –----------------(SL) Screw List (U1-U9)
Screw Count----------------(SC) Screw Count (1-99)
OKAll alarm time----------(At) OKALL Alarm time ( 0.1 ~ 9.9Sec)
when batch complete
Slow Start Time------------(RC) Slow Start Time ( 0.1 ~ 9.9Sec)
Speed Level ----------------(SP) Slow Start Speed (Full speed activated when
slow start time reached)
Max Fasten Thread---------(HC)Hi Thread (max. no. of fastening threads)
Min Fasten Thread----------(LC)Low Thread (min. no. of fastening threads)
Max Fasten Time-----------(Ht) Max. fastening time ( 0.1 ~ 9.9Sec)
Min Fasten Time------------(Lt) Min. fastening time ( 0.1 ~ 9.8Sec)
Local(In-place) shutoff-----(LS) To judge double hit
NG stop-----------------------(NS) Whether to lock the screwdriver or not when
error occurred
OK ALL stop----------------(AS) Whether to lock the screwdriver or not when a
batch complete
Gear Box Ratio--------------(GR) Gear ratio
POWER LED
(Red LED on bottom)
Red LED on when low voltage
LED_OK
(Greed LED on top)
Green light on when a tightening correctly completed
LED_NOK
(Red LED on top)
Red light on when tightening time is higher or lower than max. and min
fastening time settings.
LED_OK ALL
(Green LED on top)
Greenlight on when 1 screw tightening complete or 1 batch complete.
KEY LOCK
To lock, turn the key clock wise, then operator cannot enter program setting
menu. LCD display will show a locked icon.
To unlock, turn the key counter clock wise. LCD display will show a unlock
icon.