12
3.
Set up functions
Functions
Settings
Description
Default
setting
1.SL
Screw list from U1-U9
U1
2.SC
Screw count number from 1-99
Count method: count down
5
3.At
When a batch completed, OKALL alarm signal will last for 0.1 ~ 9.9 sec..
Meanwhile buzzer and OK ALL alarm signal will active simultaneously.
2.0 sec.
4.RC
Slow start setting. Slow start stop cannot exceed Ht period. Slow start
speed depends on SR setting. When slow start time reached, the
screwdriver will run at full speed.
0.0 sec.
5.SP
Slow start speed ( L0/L1/L2/L3/L4/L5/L6/L7/L8/L9)
L0
:
100% L1~L9
:
30%~90%
L0
6.HC
Max. no. of thread fastening (00.1 ~ 99.9)
When screwdriver shuts off exceed max. no. of thread fastening setting or
not shut of properly, LCD display will show NOK with buzzer alarm.
99.9
7.LC
Min. no. of thread fastening (00.1 ~ 99.9)
When screwdriver shuts off before reaching min. no. of thread fastening
setting or not shut off properly, LCD display will show NOK with buzzer
alarm.
00.0
8.Ht
Max. fastening time 0.1 ~ 9.9 sec.
When fastening time is longer than max. fastening time setting, LED will
show NOK with buzzer alarm.
2.00 sec.
9.Lt
Min fastening time 0.00 ~ 9.98 sec.
When LT set as 0.00. LCD will show OK with green LED on when
tightening time is correspond to HT setting.
When LT set as 0.01 sec. LCD will show NOK with buzzer alarm, when
tightening time exceed HT setting.
0.10 sec.
10.LS
When fastening no. of thread is smaller than LS setting, it will judge this
fastening as double and will not count this fastening.
10
11.NS
When triggered, whether to lock the screwdriver or not. LCD display will
show NOK with buzzer alarm.
When NS is triggered, need to press Confirm (S) to unlock screwdriver to
do the next job.
NS will be triggered when screwdriver shut off outside of Ht and Lt
settings or not shut off properly.
[N]
12.AS
Whether to lock the screwdriver or no when a batch complete.
When AS is triggered, need to press Confirm (S) to unlock screwdriver to
do the next job.
[N]
13.GR
Set gear ratio
14.5