H5CLR

TIMER

Operating  voltage

Allowable  operating
voltage  range

Rated  frequency

Contact  rating

Reset time

Power  consumption

Life

Ambient  temperature

Ambient  humidity

Weight

Mechanical : 5,000,000 times  /  Electrical : 100,000 times

85 ~ 110% of  rated  operating  voltage

50 / 60Hz

MAX 0.1s

250VAC 5A (Resistive  load)

Approx.  2.5VA

-10

Д

+50

°

C

MAX 85% RH

Approx.  120g(H5CLR) / 150g(ASY-4DR)

AC/DC : 12

Д

48V / AC/DC : 100

Д

240V

NAMES AND FUNCTIONS OF FACEPLATE

SPECIFICATIONS

SETTING PROCEDURE

CONNECTION

P r o d u c t   i s   s u b j e c t   t o   c h a n g e   w i t h o u t   n o t i c e .

Upper display

Display PV values (current time, etc.) or 
setup items.

Lower display

Display SV values (set time, etc.) and 
other parameter values.

key :

Used for incrementing or decrementing 
numeric values.

Performing arithmetic shift operations and 
switches the display. Hold down for at least 
3 seconds to enter setting modes.

LEDs

RUN: Timing indicator
OUT: Control output indicator
K/P: Key protection indicator
RESET: Reset indicator
START: Start indicator
GATE: Gate indicator
h: Time unit display (Hour)
m: Time unit display (Minute)
s: Time unit display (Second)

     key :

Reset the output or save the value 
of setting.(after save than back to 
the operation mode)

key :

RESET

POWER ON

or

RESET

Reset

SPECIAL FUNCTION KEY

TIME RANGE

9.999s

Select the 
time range

Switch to output

 setting mode

OUTPUT MODE

Select

output mode

Switch to count up/down

setting mode

UP / DOWN MODE

Select count up 

or count down

Switch to input signal

 time setting mode

INPUT SIGNAL TIME

Select input 

signal time

ϡ

 Mode A1,A2,A3,B1,B2,C,D and F are not available on ASY-4DR

ϭ

 and H5CLR-8 

OUTPUT TIME

Select 

output time

ϡ

 Not functionable on MODE C,D,E and F

ϡ

 Not available for ASY-4DR

ϭ

 and H5CLR-8

Switch to key protection level

 setting mode

KEY PROTECTION LEVEL

Select key

protection level

Switch to output contact

 setting mode

OUTPUT CONTACT

Select output 

contact

ϡ

 Available on H5CLR-8/-11 and ASY-4DR

ϭʳ

type only

Switch to time range

 setting mode

H5CLR-8 & ASY-4DR

ϭ

H5CLR-8G & ASY-4DRG

ϭ

H5CLR-11

H5CLR-11M

H5CLR-11M I

H5CLR / ASY- 4DR

MULTI-FUNCTION DIGITAL TIMER

User's Manual

SAFETY  PRECAUTION

This manual uses the following symbols to ensure safe operation of this timer.

WARNING
CAUTION

Warnings are indicated when mishandling this product might result in death or serious injury 

Cautions are indicated when mishandling this product might result in minor injury to the user, 

to user.

or only physical damage to the timer.

Θ

Note this incorrect wiring of this product can damage it and lead to other hazards. Make sure the product has 

    been correctly wired before turning the power ON.

Θ

Before wiring, or removing / mounting the product, be sure to turn the power OFF. Failure to do so might cause 

    electric shock.

Θ

Do not touch electrically charged parts such as the power terminals. Doing so might cause electric shock.

Θ

Do not disassemble the product. Doing so might cause electric shock or faulty operation.

Θ

Use the product within the operating ranges recommended in the specification (temperature, humidity, voltage, 

    shock, mounting direction, atmosphere and etc.). Failure to do so might cause fire or faulty operation.

Θ

Firmly tighten the wires to the socket. Insufficient tightening of the wires to the socket might cause fire.

WARNING

CAUTION

RESET

99.99s
999.9s

Count up
Count down

9999s

999.9m
9999m
999.9h
9999h

99m59s
99h59m

Hold
0.1s

20ms
1ms

0.5s

1s
5s
10s

15s
20s

Mode A
Mode A1
Mode A2
Mode A3

Lock function key
Lock reset key

2C
1A1C

Lock preset value key
Lock all key

Mode B
Mode B1
Mode B2
Mode C

Mode D
Mode E
Mode F

See reverse page for more details

Switch 

ON / OFF Key 

protection

PRESS FOR 3s

PRESS FOR 3s

Switch to input setting mode

RESET

Switch to input setting mode

(1)Stop

(2)Timing

PRESS 

FOR 3s

PRESS 

FOR 3s

or

Switch to input setting mode

RESET

RESET

Save and back to the 
operation mode

or

RESET

Save and back to the 
operation mode

or

RESET

Save and back to the 
operation mode

or

RESET

Save and back to the 
operation mode

or

RESET

Save and back to the 
operation mode

or

RESET

Save and back to the 
operation mode

or

Switch to output time

 setting mode

RESET

Save and back to the 
operation mode

or

K / P : Key Protection

PNP type

K / P : Key Protection

NPN type

When using this product in applications 
that require particular safety or when 
using this product in important facilities, 
please pay attention to the safety of the 
overall system and equipment. Install fail-
safe mechanisms, perform redundancy 
checks and periodic inspections and 
adopt other appropriate safety measures 
when it is necessary. This product is rated 
at Class 

     .

RESTRICTIONS ON USE

SOURCE

3

2

1

8

9

10

11

7

6

5

4

START

GATE

K / P

RESET

(Sensor)

+12VDC(50 mA)

Load

(-)

(+)

N

L

3

2

1

8

9

10

11

7

6

5

4

START

GATE

K / P

(Sensor)

Common (0V)

12 VDC(50 mA)

Load

(-)

(+)

RESET

SOURCE

N

L

3

2

1

8

9

10

11

7

6

5

4

T.D. INST.

RESET

START

SOURCE

N

L

4

3

2

1

8

7

6

5

RESET

START

SOURCE

N

L

T.D. INST.

4

3

2

1

8

7

6

5

SOURCE

N

L