2-19 User Level Calibration Commands
Programming with GPIB Commands
2-56
PN: 10370-10374 Rev. F
MG369xC GPIB PM
Name: Level Correction Offset
Description: This is the power level that is added to the front panel power before the level correction
point table power levels are subtracted. It represents the maximum power deviations read during the
calibration.
Type: Integer
Offsets (base 16): Table #1
0036
Table #2
06B4
Table #3
0D32
Table #4
13B0
Table #5
1A2E
Units: mdB (milli-dB)
Name: Level Correction Point Table
Description: These are the power level correction values with respect to the maximum power deviation
read during the calibration.
Type: Short (Array of 801 Points)
Offsets (base 16): Table #1
003A
Table #2
06B8
Table #3
0D36
Table #4
13B4
Table #5
1A32
Units: mdB (milli-dB)
Name: Power Meter Frequency Offset Table
Description: This is the frequency offset added to the synthesizer's frequency before sending it to the
power meter for the sensor correction factor.
Type: Double
Offsets (base 16): Table #1
0016
Table #2
0694
Table #3
0D12
Table #4
1390
Table #5
1AE0
Units: mHz (millihertz)
Name: Power Meter Frequency Scale Table
Description: This is the scale factor applied to the synthesizer's frequency before sending it to the power
meter for the sensor correction factor.
Type: Double
Offsets (base 16): Table #1
001E
Table #2
069C
Table #3
0D1A
Table #4
1398
Table #5
1A16
Units: mHz (millihertz)