95
4.
Confirm that the amplitude of the waveform measured by the sampling oscilloscope is in the
range according to Fig.7-2.
1Vp-p
±
0.3V
Fig.
Fig.
Fig.
Fig. 7777----2222 Specification of the clock output signal waveform
Specification of the clock output signal waveform
Specification of the clock output signal waveform
Specification of the clock output signal waveform
5.
Change Frequency on the 'Setup:Frequecny' to "1 600 001 kHz" and "50 000kHz", and test in
the same way as procedure 3 and 4. The specification at each frequency is shown below.
Frequency "1 600 001kHz" : 1,600,001kHz
±
3,200.002Hz
Frequency "50 000kHz"
: 50,000kHz
±
100Hz