background image

, p. 2

 

 

 

 

(Formerly known as Union Switch & Signal) 

Rev. 4-11 

 

MicroLok

®

 II Track Circuit PCBs 

OS Track Circuit PCB

 

 

 

Descriptions (cont’d) 

OS Tr

ack Circuit PCB (cont’d) 

detection indications are typically fed to a channel of 
the Vital Input PCB in the same MicroLok II cardfile.  It 
is not necessary to connect both receivers if it is not 
required by the application.  In many cases the 
transmitter is connected at the heel block and the two 
receivers provide independent train detection on the 
interlocking through and turnout tracks. 

The OS Track Circuit PCB is not equipped with a front 
panel and operates independently from the MicroLok II 
cardfile bus.  Four jumper locations on the board are 
used to set the OS track shunting voltage. 
 

Advantages 

 

MicroTrax and ECode PCBs provide highly flexible 
interface between the rails and the MicroLok CPU. 

 

Both PCBs highly adaptable to various interlocking 
and mainline applications. 

 

Both PCBs equipped with detailed LED indications 
for routine monitoring and diagnostics. 

 

ECode front panel permits on-unit track circuit 
adjustments. 

 

OS Track Circuit PCB ideal for intra-interlocking 
train detection, without vital relays. 

 

MicroTrax TC PCB 

 