EN
27
HOW TO USE
1. Switch to settings mode by pressing the button (6) for 5 seconds until the battery status light
starts flashing.
2. Select the required type of battery by pressing the button.
3. The set type of battery is saved automatically if the button is not pressed for 5 seconds, and the
status light stops flashing.
BATTERY TYPE INDICATOR
Status light 1
Status light 2
Status light 3
Battery type
Off
Switched on
Switched on
Sealed (standard setting)
Off
Off
Switched on
Gel (GEL)
Off
Off
Off
Wet cell (FLd)
BATTERY VOLTAGE LIMITS AND CHARGING TIMES
The voltages limits below apply for 12 V system at 25°C. Multiply by 2 for 24 V system.
Battery type
Sealed (SEL)
Gel (GEL)
Wet cell (FLd)
Overvoltage, disconnection limit
16.0 V
16.0 V
16.0 V
Charging voltage, charging stopped
15.0 V
15.0 V
15.0 V
Overvoltage, reconnection limit
15.0 V
15.0 V
15.0 V
Charging voltage, equalisation charging
14.6 V
—
14.8 V
Charging voltage, peak charging
14.4 V
14.2 V
14.6 V
Charging voltage, trickle charging
13.8 V
13.8 V
13.8 V
Charging voltage, limit for return to peak
charging
13.2 V
13.2 V
13.2 V
Undervoltage, reconnection limit
12.6 V
12.6 V
12.6 V
Undervoltage, warning stops
12.2 V
12.2 V
12.2 V
Undervoltage, warning trips
12.0 V
12.0 V
12.0 V
Undervoltage, disconnection limit
11.1 V
11.1 V
11.1 V
Undervoltage, overdischarge limit
10.6 V
10.6 V
10.6 V
Equalisation charging time
120 min
—
120 min
Peak charging time
120 min
120 min
120 min