GB
69
DESCRIPTION
• The appliance is intended for ventilation of homes and public premises heated during the winter,
and is provided with cold draught protection.
DESIGNATIONS IN WIRING DIAGRAM
L:
Live wire
N:
Neutral wire
LT:
Control wire for delay timer
QF:
Automatic fuse
S:
External switch
Sk:
External switch with
return-spring
PARTS
• 1 fan
• 1 remote control
• 1 sleeve coupling Ø100 mm
• 1 sleeve coupling Ø125 mm
• 4 screws with plugs
• 1 copy of Operating Instructions
• 1 pack
MODES
The appliance has 4 basic modes and 1 extra mode.
•
SLEEP
: the fan is off, but is ready to receive signal from sensor or external switch.
•
24 HOURS
: the fan is on all the time at low speed and provides continuous air circulation at low
level. If the air humidity increases the fan switches to MAXIMAL mode (default setting) or QUIET
mode. On a signal from an external sensor the fan switches to QUIET mode.
•
QUIET
: energy-saving mode for basic ventilation at low noise level. This mode is activated by an
external switch or humidity sensor. Humidity sensor mode must be activated from the FAN
menu.
•
MAXIMAL
: mode with maximal air flow. Activated by default by the humidity sensor.
•
INTERVAL VENTILATION
: extra mode. If the fan has not been on for 15 hours the fan starts and
runs with an air flow of 83/72 m
3
/h (Ø125/Ø100) for 2 hours. If a sensor or the external switch is
activated during this time the appliance switches to the corresponding mode.