WIRING DIAGRAM
Follow an appropriate wiring diagram to connect to the mains.
WIRING DIAGRAM 1
Automatic adjustment to humidity.
The terminals L and N are connected to live and neutral for the mains supply.
• The fan is in
SLEEP
mode and is not running.
• If
24 HOURS
mode is activated the fan runs at low speed for continuous ventilation.
• If the humidity increases the appliance switches to
MAXIMAL
mode (default setting) or
QUIET
mode. After the humidity has stabilised the appliance returns to the previous mode.
WIRING DIAGRAM 2
Permanent fan mode with automatic adjustment to humidity.
The terminals L and N are connected to live and neutral and the terminals L and LT are strapped.
• The fan motor runs continuously at low speed. Mode
24 HOURS
not available.
• If the humidity increases the appliance switches to
MAXIMAL
mode (default setting) or
QUIET
mode. After the humidity has stabilised the appliance returns to the previous mode.