ENGLISH
72
HWP – setting for circulation of hot water
1. Settings
2.
Description of settings
Menu Description
HWP Set
Setting for circulation of hot water
Temp Mode
Temperature mode setting
Time Mode
Time mode setting
OFF*
OFF, function for circulation of hot water (Default: OFF)
Temp Set
Set temperature for start and stop of circulation pump (P2)
Time Set
Set time for interval between start and stop of circulation pump (P2)
Tank Top
Sensor in top of tank
Range: 20°C~60°C (Default: 40°C)
Pipe Upper
Sensor on supply line max
Range: 20°C~45°C (Default: 38°C)
Pipe Lower
Sensor on supply line min
Range: 20°C~45°C (Default: 30°C)
1.
04:00 – 05:00
2. OFF
3.
17:00 – 22:00
Three intervals set by user for operation.
Intervals will be switched off if they are the same, e.g. 08:00-08:00
When
Temp Mode/Temperature
is set,
this symbol is shown
And when
circulation pump
is in operation,
this symbol flashes.
When
Time Mode/Tid Inst,
is selected,
this symbol is shown on display.
And when
circulation pump
is in operation,
this symbol flashes.
Summary of Contents for 417-031
Page 88: ...SVENSKA 8 Montering av kontrollpanel 1 Montering av bakstycke...
Page 89: ...SVENSKA 9 2 Montering av panel...
Page 94: ...SVENSKA 14 HT Set verhetningsskydd 1 Inst llningar...
Page 100: ...SVENSKA 20 2 Hur man s tter gr sv rdena f r automatiskt l ge...
Page 101: ...SVENSKA 21 3 Hur man ndrar viktiga v rden 4 Anv ndning av knappen...
Page 107: ...NORSK 27 Montering av kontrollpanel 1 Montering av bakstykke...
Page 108: ...NORSK 28 2 Montering av panel...
Page 114: ...NORSK 34 HT Set overopphetingsvern 1 Innstillinger...
Page 120: ...NORSK 40 2 Slik settes grenseverdier for automatisk modus...
Page 121: ...NORSK 41 3 Slik endres viktige verdier 4 Bruk av knappen...
Page 127: ...POLSKI 47 Monta panelu sterowania 1 Monta tylnej cz ci...
Page 128: ...POLSKI 48 2 Monta panelu...
Page 134: ...POLSKI 54 HT Set zabezpieczenie przed przegrzaniem 1 Ustawienia...
Page 140: ...POLSKI 60 2 Spos b ustawiania warto ci granicznych dla trybu automatycznego...
Page 141: ...POLSKI 61 3 Spos b zmiany istotnych warto ci 4 Spos b u ycia przycisku...
Page 147: ...ENGLISH 67 MOUNTING OF CONTROL PANEL 1 Mounting of back...
Page 148: ...ENGLISH 68 2 Mounting of panel...
Page 154: ...ENGLISH 74 HT Set overheating protection 1 Settings...
Page 160: ...ENGLISH 80 2 How to set limiting values for automatic mode...
Page 161: ...ENGLISH 81 3 How to change important values 4 Using the button...