Antaira Technologies - Industrial Wireless Access Points

ARS-7235-PSE-AC Series - Hardware Manual - v1.0

Diagnostics

Red

Flashing

Unit not ready / Boot sequence

Off

Unit ready

ETH Port 0

(Upper LED)

Green

On

Connected to network, 10/100/1000Mbps

Flashing

Networking is active

Off

Not connected to network

ETH Port 0

(Lower LED)

Amber

On

Link established

Off

No link detected

ETH Port 1

(Upper LED)

Green

On

Connected to network, 10/100/1000Mbps

Flashing

Networking is active

Off

Not connected to network

ETH Port 1

(Lower LED)

Amber

On

Supplying power to PD

Off

Not supplying power to PD

Table 2.1 - LED Indicators

Note:

“P1” is the abbreviation for “Power 1”, “P2” is for “Power 2”, “LNK” is for “Link”, and “ACT” is for

“Activity”.

2.5 Reset Button

There is a “reset” button located on the front panel of the industrial wireless access point that helps users

to reboot, restore default, or save running configurations by pressing the button for different seconds.

Please refer to Table 2.2 for the timing and function.

Seconds

Function

4~6

Reboot the wireless access point

7 or more

Restore factory default

Table 2.2 - Reset Button Functions

6

Summary of Contents for ARS-7235-PSE-AC Series

Page 1: ...ARS 7235 PSE AC Series Industrial Dual Radio IEEE 802 11a b g n ac Wireless Access Point Client Bridge Repeater Router with 1 PoE PSE Port 30W Hardware Manual Version 1 0 March 2022 ...

Page 2: ...ty and fitness for a particular purpose Antaira Technologies LLC may make improvements and or changes to the product and or specifications of the product described in this manual without prior notice Antaira Technologies LLC will not be liable for any technical inaccuracies or typographical errors found in this guide Changes are periodically made to the information contained herein and will be inc...

Page 3: ...nications radio si l équipement n est pas installé et utilisé conformément aux instructions Cependant il n y a aucune garantie qu aucune interférence ne se produira dans une installation particulière Si cet équipement provoque des interférences nuisibles à la réception radio ou télévision ce qui peut être déterminé en éteignant puis en rallumant l équipement l utilisateur est encouragé à essayer d...

Page 4: ...oints Industrial Grade Wireless Access Points Hardware Manual Version 1 0 March 2022 The manual supports the following models ARS 7235 PSE AC ARS 7235 PSE AC T This document is the current official release hardware manual Please check our website www antaira com for any updated manual or contact us by e mail support antaira com ...

Page 5: ...ensions 3 2 2 Front View Panel 4 2 3 Top View Panel 5 2 4 LED Indicators 5 2 5 Reset Button 6 2 6 Ethernet Ports 6 2 7 Cabling 7 2 8 Wireless Antenna 8 2 9 Wiring the Power Inputs 8 2 10 Wiring the Fault Alarm Contact 9 2 11 Grounding Note 10 3 Mounting Installation 11 3 1 DIN Rail Mounting 11 3 2 Wall Mounting 12 4 Hardware Installation 14 4 1 Installation Steps 14 4 2 Maintenance and Service 15 ...

Page 6: ...plications including long distance deployments The unit also allows the user to position the wireless antennas in a better signal broadcasting location for improved wireless coverage and signal strength or simply in a more convenient location 1 1 Product Hardware Features System Interface and Performance All RJ45 ports support the auto MDI MDI X function Embedded 2 10 100 1000Tx RJ45 ports with 1 ...

Page 7: ...iliser un dispositif de protection sur l entrée d alimentation Les spécifications matérielles les ports les informations de câblage et l installation du câblage du point d accès sans fil industriel seront décrits dans ce manuel du matériel Warning Labels The caution label means that you should check certain information on the user manual when working with the device Shown in Figure 1 1 Étiquettes ...

Page 8: ... Access Points ARS 7235 PSE AC Series Hardware Manual v1 0 2 Hardware Description 2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of this product series W x D x H is 54mm x 99mm x 142mm Figure 2 1 Physical Dimensions 3 ...

Page 9: ...ira Technologies Industrial Wireless Access Points ARS 7235 PSE AC Series Hardware Manual v1 0 2 2 Front View Panel Figure 2 2 below shows the front panel of the product series Figure 2 2 Front View Panel 4 ...

Page 10: ...and network status Each LED indicator has a different color and has its own specific meaning see below in Table 2 1 LED Color Description P1 Green On Power input 1 is active Off Power input 1 is inactive P2 Green On Power input 2 is active Off Power input 2 is inactive Fault Red On Power input 1 or 2 is inactive Off Preconfigured alarms are detecting failure Wi Fi Signal Strength Green Red Red Les...

Page 11: ...g is active Off Not connected to network ETH Port 1 Lower LED Amber On Supplying power to PD Off Not supplying power to PD Table 2 1 LED Indicators Note P1 is the abbreviation for Power 1 P2 is for Power 2 LNK is for Link and ACT is for Activity 2 5 Reset Button There is a reset button located on the front panel of the industrial wireless access point that helps users to reboot restore default or ...

Page 12: ...nts Crossover Cable Straight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 RX 3 TX 1 RX 1 TX 2 RX 6 TX 2 RX 2 TX 3 TX 1 RX 3 TX 3 RX 6 TX 2 RX 6 TX 6 RX Table 2 2 10 100Base T X RJ45 Pin Assignments Crossover Cable Straight Through Cable Pin Number Signal Pin Number Signal Pin Number Signal Pin Number Signal 1 TP0 3 TP1 1 TP0 1 TP1 2 TP0 6 TP1 2 TP0 2 TP1 ...

Page 13: ... The 2 4GHz 5GHz antennas are connected with SMA connectors Other external antennas can be used 2 9 Wiring the Power Inputs Caution Please follow the steps below when inserting the power wire Attention Veuillez suivre les étapes ci dessous lors de l insertion du câble d alimentation 1 Insert the positive and negative wires into the PWR1 V1 V1 and PWR2 V2 V2 contacts on the terminal block connector...

Page 14: ...e picture shows below in Figure 2 8 By inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch only and form a normal open circuit An example is shown below in Figure 2 8 Figure 2 8 Wiring the Fault Alarm Contact Caution The wire gauge for the terminal block should range between 12 24 AWG If only using one power source jumper Pin 1...

Page 15: ...omagnetic Interference EMI Run the ground connection from the ground screw to the grounding surface prior to connecting devices The grounding screw symbol is shown below in Figure 2 9 Figure 2 9 Grounding Screw Symbol Caution Using a shielded cable achieves better electromagnetic compatibility Attention L utilisation d un câble blindé permet une meilleure compatibilité électromagnétique 10 ...

Page 16: ...all the DIN Rail bracket on the rear side of the industrial wireless access point Caution The torque for tightening the screws on the device is 3 5 in lbs Attention Le couple de serrage des vis sur l appareil est de 3 5 pouces livres 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the wireless access point insert the top of...

Page 17: ... wall Attention Wall signifie mur de panneau de commande industriel 1 Remove the DIN Rail bracket from the industrial wireless access point by loosening the screws 2 Place the wall mounting brackets on the top and bottom of the industrial wireless access point 3 Use the screws to screw the wall mounting bracket on the industrial wireless access point Caution The torque for tightening the screws on...

Page 18: ...hnologies Industrial Wireless Access Points ARS 7235 PSE AC Series Hardware Manual v1 0 5 To remove the wall mount bracket do the opposite from the steps above Figure 3 4 Remove DIN Rail bracket from the Switch 13 ...

Page 19: ...nt If the DIN Rail is not screwed on the industrial wireless access point please refer to the DIN Rail Mounting section for DIN Rail installation If it is required to wall mount the industrial wireless access point please refer to the Wall Mounting section for wall mounting installation 3 To hang the industrial wireless access point on a DIN Rail or wall please refer to the Mounting Installation s...

Page 20: ...sipation holes located in the different faces of the device This may not only harm the internal layout but might cause harm to users as well Do not under any circumstance open the device for any reason Please contact your dealer for any repair needed or follow the instructions within the manual Clean the device with dry soft cloth 4 3 Troubleshooting Always verify the right power cord or adapter i...

Page 21: ... a problem with the power cord Check for loose power connections power losses or surges at the power outlet Please contact Antaira for technical support service if the problem still cannot be resolved If the industrial switch LED indicators are normal and the connected cables are correct but the packets still cannot transmit please check the system s Ethernet devices configuration or status 16 ...

Page 22: ... SNMP WLAN Operation Modes AP Client Bridge Repeater Router Encryption Security WPA WPA2 WPA3 WEP TKIP AES RADIUS 802 1x EAP Interface Ethernet Ports 2 10 100 1000Tx with 1 PoE PSE PSE 30W WLANs Dual Band 2 4GHz 5GHz concurrent Antennas 2 External SMA Antennas 3dBi for 2 4GHz 5dBi for 5GHz MIMO support Dual 2Tx Rx LED Indicators Power Fault Wi Fi Signal Link Activity Frequency Range IEEE 802 11a b...

Page 23: ...emperature 40 C 80 C Ambient Relative Humidity 5 to 90 non condensing Regulatory Approvals EMI FCC Part 15 Subpart B CE EN55032 EMS CE EN55024 IEC61000 4 2 3 4 5 6 8 11 Free Fall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 Green RoHS Compliant Certifications FCC CE Warranty 5 Years Table 5 1 Technical Specifications Antaira Customer Service and Support Antaira US Headquarter 844 268 2...

Page 24: ...ira Technologies Industrial Wireless Access Points ARS 7235 PSE AC Series Hardware Manual v1 0 www antaira com tw info antaira com tw Any changes to this material will be announced on the Antaira website 19 ...