Antaira Industrial Ethernet Switches
LMP-0602-24 Series User Manual V1.1
16
Terms
Value Description
New Password
Users can assign a New Password, and the maximum allow string
length is 0 to 31 characters.
Confirmation
Re-type the new password.
Click “Apply” to save changes.
5.2.3 IP Setting
Configure the managed switch’s IP setting information.
Terms
Value Description
DHCP Client
Enable the DHCP client by checking this box.
If DHCP fails and the configured IP address is zero, DHCP will retry. If
DHCP fails and the configured IP address is non-zero, DHCP will stop
and the configured IP settings will be used. The DHCP client will
announce the configured System Name as hostname to provide DNS
lookup.
IP Address
The unit default IP is 192.168.1.254.
Assign the IP address that the network is using. If DHCP client function
is enabling, user does not require assigning the IP address. The
network DHCP server will assign the IP address for the switch and it will
be display in this column.
Figure 5.7 – IP Setting information
Figure 5.6 – Admin & Password Description