Antaira Technologies - Industrial Ethernet Switches
LMX-1002G-SFP Series Hardware Manual V1.4
11
Caution:
The wire gauge for the terminal block should range between 12 ~ 24AWG
If only using one power source, jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to
eliminate power fault alarm.
2.10 Grounding Note
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the
ground connection from the ground screw to the grounding surface prior to connecting devices. The
grounding screw symbol is shown blow in Figure 2.15.
Figure 2.15 - Grounding screw
Caution:
Using a shielded cable achieves better electromagnetic compatibility.