background image

 

Quick Installation

 

Ethernet Ports 
M12 Ports (Auto MDI/MDI-X) 

All M12 ports (8-Pin X-Coded Female Connector) are auto-sensing for 
10Base-T, 100Base-TX, or 1000Base-T device connections. Please 
follow the wiring pin assignment table below for Ethernet port installation. 

Illustration 

Pinouts 

10/100Base-T(X) 

Signal 

1000Base-T 

Signal 

 

1

 

Transmit Data + (TX+) 

BI_DA+ 

2

 

Transmit Data - (TX-) 

BI_DA- 

3

 

Receive Data + (RX+) 

BI_DB+ 

4

 

Receive Data – (RX-) 

BI_DB- 

 

BI_DD+ 

 

BI_DD- 

 

BI_DC- 

 

BI_DC+ 

NOTE

: Recommended use the wire gauge between 18AWG. 

Power Input Wiring 

   Dual DC power inputs for power redundancy 

   Connection format: M12 5-Pin K-Coded male connector 

   Pin assignment of M12 power connector: 

Illustration 

Pinouts 

Function 

 

Power Input 1 + (V1+) 

Power Input 1 - (V1-) 

Power Input 2 - (V2-) 

Power Input 2 + (V2+) 

GND 

NOTE

: Recommended use the wire gauge between 24AWG. 

Console Port 

 

Connection format: M12 5-Pin A-Coded Female Connector 

 

Baud rate 115,200bps, 8, N, 1 

Illustration 

Pinouts 

Signal 

 

NC 

TX 

RX 

NC 

GND 

USB Port 

 

Connection format: M12 4-Pin A-Coded Female Connector 

 

USB Port is for configuration backup / restore 

Illustration 

Pinouts 

Function 

 

DN 

VBUS 

GND 

DP 

 

 
 

Relay Contact and Digital Input 

 

Connection format: M12 5-Pin A-Coded Male Connector 

 

Minimum Wire Gauge: 24AWG

 

Illustration 

Pinouts 

Function 

Function 

 

DI+ Relay Com 

Common 

2

 

DI+ 

Digital Input + 

3

 

DI- 

Digital Input - 

4

 

DI- Relay (N.C.) 

Normally Closed 

NA 

Not Assigned 

 

 

Digital Input (DI) 
The digital input is used for monitoring two external events via an 
external voltage source. When the voltage level on digital input pins 
changes from high voltage to low voltage, the DI function will be 
triggered. Below table is shown a detail specification of the digital 
input. 

Specification 

Description 

Level 0 (Low) 

-30~8VDC 

Will trigger DI function 
(active trigger states) 

Level 1 (High) 

10~30VDC 

Normal Status 
(inactive trigger states) 

Nominal input voltage 

24VDC 

 

Max. input voltage 

30VDC 

 

Nominal input current 

5mA (typical) 

 

Max. input current 

8mA 

 

Reset to Default 

Please perform the below steps to reset the switch to factory default 
setting. 

Step 1.

 

Reverse the Tx & Rx of the Console Cable and plug it into the 
console port. 

Step 2.

 

Restart the power. 

Step 3.

 

The switch will start rebooting with the port LEDs flashing. 

Step 4.

 

When the Status LED turns into Green, the process is 
completed. 

Step 5. 

Remove the reversed console cable. 

Bypass Function 

This Ethernet switch supports bypass function by two Ethernet ports (8 
and 16). When one of the Ethernet switches loses power, Ethernet ports 
(8 and 16) will bypass the power lost Ethernet switch to prevent the 
network from disconnecting. 
 

 

 

SFP Installation 

 

 
Wall Mounting Installation 

Follow the steps below to mount the switch to a wall using the screw 
holes. 

 

 

Step 1.

 

Prepare 4 screws for mounting the switch to a wall. 
(Recommended use the M5 screws.) 

Step 2.

 

Based on the positions of 4 screw holes on the left and 
right side of the switch to make 4 screw holes on a wall 
accordingly.

Step 3.

 

Insert the screws through the screw holes on the switch 
and screw the switch into the wall. 

Step 4.

 

To remove the switch from the wall, do the opposite from 
the steps above. 

Antaira’s Customer Service and Support   

 

Antaira’s Technical Service & Support Centers: 

          + 844-268-2472        (Antaira US Headquarter) 
          + 48-22-862-88-81    (Antaira Europe Office) 
          + 886-2-2218-9733    (Antaira Asia Office) 
 

 

Antaira’s Web Sites & Repair/Support Emails: 

www.antaira.com

 / 

support@antaira.com

 

www.antaira.eu

 / 

info@antaira.eu

 

www.antaira.com.tw

 / 

info@antaira.com.tw

 

 

*Any changes will be announced on the Antaira website.

 

Reviews: