Antaira Technologies - Industrial Ethernet Switches
LMX-2602G-SFP Series Hardware Manual V1.0
7
2.5 Reset Button
There is a ‘Reset’ button located on the front panel of the industrial Ethernet switch that helps
users to reboot, restore default, or save running configurations by pressing the button for
different seconds. Please refer to
Table 2.2
for the timing and function.
Seconds
Function
Fault LED
0s < t (press time) < 4s Reboot the switch
LED is flashing with green color
4s < t (press time) < 8s Restore factory default
LED is flashing with green and red color
8s < t (press time)
Backup configuration to USB
(startup-config)
LED is flashing with red color
Table 2.2
– Reset Button Functions
2.6 Ethernet Ports
◼
RJ45 Ports (Auto MDI/MDIX):
The RJ45 ports are auto-sensing for 10/100/1000Base-Tx devices connections. Auto MDI/MDIX means
that the switch can connect to another switch or workstation without changing the straight-through or
crossover cabling. See the figures shown below for straight-through and crossover cabling schematics.
◼
RJ-45 Pin Assignments
The following figures show the cabling schematics for straight-through and crossover cables.
Figure 2.3 Figure 2.4
Straight-Through Cables Schematic Crossover Cables Schematic