background image

Antaira Technologies - Industrial Ethernet Switches 

LNP-1604G-SFP Series User Manual V1.1 

 

 

2.4  LED Indicators 

There are LED light indicators located on the front panel of the industrial Ethernet switch that 

display the power status and network status. Each LED indicator has a different color and has 

its own specific meaning, see below in Table 2.1

 

LED 

Color 

Description 

 

Power 1 

 

Green 

    On 

Power input 1 is active 

    Off 

Power input is inactive 

 

Power 2 

 

Green 

    On 

Power input 2 is active 

    Off 

Power input is inactive 

 

Fault 

 

  Red 

    On 

Power input 1 or 2 is inactive 

    Off 

Both power input 1 and 2 are active 

 

PoE Status 

 

  Red 

    On 

The port is supplying power to the powered-device 

    Off 

No powered-device attached or power supplying fails 

 

 
 
 

Link Activity 

(SFP Port) 

 

 
Green 

        On 

Connected to the network with 1000Mbps 

    Flashing 

Networking is active   

        Off 

Not connected to the network 

 
 

Amber

 

        On 

Connected to the network with 100Mbps 

    Flashing 

Networking is active 

Off 

Not connected to the network 

 

LAN Port 1 ~ 12 

(Upper LED) 

 

Green 

 

On 

Connected to network, 1000Mbps 

Flashing       

Networking is active 

Off 

Not connected to network 

 

LAN Port 1 ~ 12 

(Lower LED) 

Green 

 

 

 

On 

Connected to network, 10/100Mbps 

Flashing 

Networking is active 

Off 

Not connected to network 

 

 

 

 

 

 

 

 

 

 

 

Table 2.1 

  LED Indicators for LNP-1604G-SFP Series 

Summary of Contents for LNP-1604G-SFP Series

Page 1: ...ustrial Ethernet Switches LNP 1604G SFP Series User Manual V1 1 i LNP 1604G SFP Series 16 Port Industrial Gigabit PoE Unmanaged Ethernet Switches with 12 10 100 1000Tx PSE 30W Port 4 100 1000 SFP Slots Version 1 1 User Manual ...

Page 2: ...rs Notice Copyrights 2018 by Antaira Technologies LLC All rights reserved Reproduction adaptation or translation without prior permission of Antaira Technologies LLC is prohibited except as allowed under the copyright laws Disclaimer Antaira Technologies LLC provides this manual without warranty of any kind expressed or implied including but not limited to the implied warranties of merchantability...

Page 3: ...ged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Caution Any changes or modifications not expres...

Page 4: ... Description 3 2 1 Physical Dimensions 3 2 2 Front Panel 4 2 3 Top View 4 2 4 LED Indicators 5 2 5 Ethernet Ports 6 2 6 Cabling 7 2 7 Wiring the Power Inputs 9 2 8 Wiring the Fault Alarm Contact 9 3 Mounting Installation 10 3 1 DIN Rail Mounting 10 3 2 Wall Mounting 11 4 Hardware Installation 12 4 1 Installation Steps 12 5 Network Applications 13 6 Trouble Shooting 14 7 Technical Specifications 15...

Page 5: ... machine vision process control automation and intelligent transportation This product series provides high EFT and ESD protection with a redundant power input support of 48 55VDC There are two wide operating temperature models to support either a 10 to 70 C or 40 to 75 C environment 1 1 Key Features System Interface Performance All RJ 45 ports support the auto MDI MDI X function Ethernet connecti...

Page 6: ... 12 10 100 1000Tx 4 100 1000 SFP slots 2 Wall mounting brackets and screws 1 DC cable 18 AWG DC jack 5 5x2 1mm 1 3 Safety Precaution Attention If the DC voltage is supplied by an external circuit please use a protection device on the power supply input The industrial Ethernet switch s hardware specs ports cabling information and wiring installation will be described within this user manual ...

Page 7: ...2 1 Physical Dimensions Figure 2 1 below shows the physical dimensions of Antaira Technologies LNP 1604G SFP series 16 port industrial Gigabit PoE unmanaged Ethernet switches with 12 10 100 1000Tx PSE 30W Port 4 100 1000 SFP slots W x D x H is 59mm x 99mm x 142mm Figure 2 1 LNP 1604G SFP Series Physical Dimensions ...

Page 8: ...e top panel of the LNP 1604G SFP series switch that is equipped with one 6 pin removal terminal block connector for dual DC power inputs 48 55 VDC Figure 2 2 Front Panel of the LNP 1604G SFP Series Figure 2 3 Top Panel View of LNP 1604G SFP Series LAN 1 12 LED for 1000Mbps LAN 1 12 10 100 1000 RJ45 LAN 1 12 LED for 10 100Mbps Grounding Screw 6 Pin Removal Terminal Block Power Input LED for Power 1...

Page 9: ...input 1 or 2 is inactive Off Both power input 1 and 2 are active PoE Status Red On The port is supplying power to the powered device Off No powered device attached or power supplying fails Link Activity SFP Port Green On Connected to the network with 1000Mbps Flashing Networking is active Off Not connected to the network Amber On Connected to the network with 100Mbps Flashing Networking is active ...

Page 10: ...atic MDI MDI X operations Users can use straight through cables see figure below for all network connections to PCs servers and other switches or hubs With straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below Table 2 3 shows the 10BASE T 100BASE TX 1000BASE T and MDI MDI X port pin outs Note...

Page 11: ...nnected with an unshielded twisted pair UTP or shielded twisted pair STP cable The cable must comply with the IEEE 802 3u 100Base TX standard e g Category 5 5e or 6 6e The cable between the equipment and the link partner switch hub workstation etc must be less than 100 meters 328 ft long Note Cable size should be between 18 20 AWG and the torque should be tightened to 5lbs Figure 2 4 Figure 2 5 St...

Page 12: ...e SFP slot Figure 2 8 shows SFP transceiver module was inserted Second insert the fiber cable of the LC connector into the transceiver as shown below in Figure 2 9 To remove the LC connector from the transceiver please follow the steps shown below 1 Press the upper side of the LC connector from the transceiver and pull it out to release as shown below in Figure 2 10 2 Push down the metal clasp and...

Page 13: ...k should range between 18 20 AWG 2 8 Wiring the Fault Alarm Contact The fault alarm contact is in the middle of the terminal block connector as the picture shows below in Figure 2 14 By inserting the wires it will detect the fault status including power failure or port link failure managed industrial switch only and form a normally open circuit An application example for the fault alarm contact is...

Page 14: ... 2 To remove the DIN Rail bracket do the opposite from step 1 3 After the DIN Rail bracket is installed on the rear side of the switch insert the top of the DIN Rail on to the track as shown below in Figure 3 2 4 Lightly pull down the bracket on to the rail as shown below in Figure 3 3 5 Check if the bracket is mounted tightly on the rail 6 To remove the industrial Ethernet switch from the rail do...

Page 15: ...the wall mounting brackets on the top and bottom of the industrial Ethernet switch 3 Use the screws to screw the wall mounting bracket on the industrial Ethernet switch 4 Use the hook holes at the corners of the wall mounting bracket to hang the industrial Ethernet switch on the wall 5 To remove the wall mount bracket do the opposite from the steps above Figure 3 5 below has the dimensions for the...

Page 16: ...ing section for wall mounting installation 3 To hang the industrial Ethernet switch on a DIN Rail or wall please refer to the Mounting Installation section 4 Power on the industrial Ethernet switch and then the power LED light will turn on For the help on how to wire power please refer to the Wiring the Power Inputs section Please refer to the LED Indicators section for LED light indication 5 Prep...

Page 17: ...Antaira Technologies Industrial Ethernet Switches LNP 1604G SFP Series User Manual V1 1 13 5 Network Applications Figure 5 1 Industrial PoE Networking Application Reference ...

Page 18: ...d 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored with the LED indicators which help to identity if any problems exist o Please refer to the LED Indicators section for LED light indication If the power indicator LED does not turn on when the power cord is plugged in the user may have a problem with the power cord Check for loose po...

Page 19: ...bo Frame 12 2Kbytes MAC Table Size 8K MAC Address Port Interface Ethernet RJ45 Port 12 10 100 1000Tx PSE 30W port auto negotiation speed full half duplex mode and auto MDI MDI X connection PoE Port Pin Out V V V V for pin 1 2 3 6 Endspan MDI Alternative A Fiber Port 4 100 1000 SFP Slots Fiber Wavelength Refer to SFP Modules LED Indicator Power 1 Power 2 Fault Ethernet Ports On Link Flash data tran...

Page 20: ...IEC 61000 4 8 Magnetic Field Stability Testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration Green RoHS Compliant Compliance EN50121 4 Railway NEMA TS1 TS2 ITS Safety Certificate FCC CE Warranty 5 Years Table 7 1 LNP 1604G SFP Series Technical Specifications Antaira Customer Service and Support Antaira US Headquarter 844 268 2472 Antaira Europe Office 48 22 862 88 81 Antaira A...

Reviews: