A black square metal mesh is located at the back of the machine. This is the air
inlet of the fan. Please do not block the inlet and clean it routinely to keep the
cleanness.
5-4
If the fog volume is too low, the machine generates noise during operation or the
fog cannot be smoothly sprayed, please turn off the power immediately and check
if the fog fluid is sufficient, whether the external fuse, controller connection or power
supply has any problem. If none of the above shows any problem, insert the power
plug again. If the machine still cannot normally operate, please check whether the
hose connecting to the fog fluid tank is blocked, and if any fluid is flowing. If the
cause cannot be identified, please do not allow the machine to operate to avoid
damage. Turn off the machine Immediately and let it cool down. Please contact an
Antari dealer or a designated service center. Do not disassemble the machine by
yourself.
5-5
After using the DNG-250 for a long time, there may be residue on the floor which
could be a possible cause of danger. Please note the material of the floor and pay
special attention to the safety of persons walking on it.
5
-6
The DNG-250 Low Fog Generator does not use dry ice. It is very environmental
friendly and safe. However, the output fog is easily to be blown away by wind.
Please
note the air flow’s impact from fan or air conditioner.
Maintenance of the Machine
6
-
1
Cleaning your fog machine regularly will help reduce costly replacement and repair
charges.
6
-2
Do not allow the fog fluid to become contaminated. The cap should be on the tank
at all times.
Figure 6
Figure 7