Low Pressure Threshold Chart
Model
Power Up
Power Down
1600
2800 psi
350 psi
2000
2800 psi
2500
1850 psi
WARNING
Do not stand or work in the
platform’s work area while
operating the liftgate. Place
the pressure gauge so it can be read while operating the
liftgate from a safe location. Serious injury or death
could result if this action is not followed.
5. To adjust the pressure, loosen the lock nut and
turn Allen screw clockwise to increase pressure or
counterclockwise to decrease the pressure.
Retighten
locknut, and retest the pressure setting.
Note: To rest the pressure from zero, turn the adjusting
screw in all the way, then back out one full
turn. Retighten lock nut, test liftgate with load.
If liftgate performs well, set pump pressure
according to factory settings.
858
857
7
6. Check the “power down” relief valve pressure in the
same way as the “power up” by installing a T-fitting and
pressure gauge in the power down port.
4.12 Checking Flow Control Valve
856
If the cylinder does not operate or operates slower than
normal, remove the flow control valve and hook the
hydraulic hose directly to the cylinder. If the cylinder
operates properly, replace the flow control valve.
Replacement part — A-130102.
WARNING
Do not operate the liftgate
without the flow control
valve. Serious injury or
death could result if this action is not followed.
4.13 Control Switch Fuse - 10 Amp
If the control switch is not operating the liftgate, check the
in-line fuse located on the control cable inside the power
unit box. Replace with A-150438 10A Fuse.
ALI-00596
ALI-00597