Anthony Lifgtates, Inc.
20
L-501 Models
www.anthonyliftgates.com
800-482-0003
5.5 Liftgate Wiring Diagram
ALI-00089
+
–
Ground
Long
Power
Cable
M
200 Amp Fuse
Vehicle
Battery
Liftgate
Solenoid
Ground
to
Chassis
Liftgate
Pump/Motor
NO LESS THAN
6” OF SLACK
LEAVE SLACK IN CABLE.
NEEDED WHEN REPLACING FUSE
FUSE HOLDER SECURED WITH
FASTENERS. (2 PLACES)
MAKE SURE BATTERY IS
GROUNDED TO CHASSIS
FRAME WITH 4 GAGE WIRE
OR LARGER
MAKE SURE POWER UNIT IS
GROUNDED TO CHASSIS
FRAME WITH 4 GAGE WIRE
OR LARGER
TO LIFTGATE SOLENOID
Vehicle
Starter
Solenoid
NOTE:
1 - Fuse should be placed in an
easily accessible location within
30” of the battery.
2 - Leave a minimum of 6” of slack
in the cable for replacing fuse.
+
–
Ground
Long
Power
Cable
M
200 Amp Fuse
Cutoff
Switch
Cutoff
Switch
Vehicle
Battery
Liftgate
Solenoid
CONNECTION TO VEHICLE BATTERY
CONNECTION TO VEHICLE SOLENOID
(ALTERNATE CONNECTION METHOD)
Ground
to
Chassis
Liftgate