background image

Anthony Liftgates, Inc. 

 

16 

MTU-GLR Maintenance

www.anthonyliftgates.com  

800-482-0003

5.  Decals

5.1  Installing Decals

 

SAFETY

 INSTRUCTIONS

N ING

AR

To prevent possible 

injuries due to improper 

operation, make sure all 

decals are attached to the liftgate and truck and are 

legible.

1.  Attach decals 1, 2, 3, 4, and 5 to the truck body, as 

shown.

Operation

 may requ

ire user t

o stand o

n platform

.

To preven

t injury or

 death of 

operators

 or bystan

ders:

•  Read an

d follow o

perator/o

wner man

ual for sa

fety,

operation

, inspecti

on, and m

aintenanc

e instruct

ions.

•  Do not p

lace unst

able or un

safe load

s on platf

orm.

•  Do not a

llow load

s to exten

d over ed

ge of plat

form.

•  Do not a

llow body

 parts to 

contact m

oving com

ponents.

•  Ensure 

footing is

 stable an

d stand a

way from

 edge

before ra

ising or lo

wering pl

atform.

•  Owner/o

perators 

must prop

erly main

tain liftga

te.

•  Do not e

xceed ca

pacity or 

use liftga

te for any

thing

other tha

n intende

d purpose

.

•  Be awa

re of surr

oundings

 when op

erating li

ftgate.

WARNING

A-131115 

PERSONA

L INJURY

 HAZARD

A-131012

03/2008

1200 lb.

5

ALI-00599

1

2

3

4

2.  Make sure factory-installed decals 6, 7, and 8 are 

attached to the lift arms and platform.

ALI-00600

A-

15

06

01

A-

13

10

17

03

/2

00

8

6

7

8

3.  Make sure the factory-installed fuse changing decal 

10 is on the power cable and is visible near the 

location of the fuse. (attached only to A-133105 200 

AMP Power Cable)

ALI-00393

10

4.  Make sure factory-installed decals 11, 12, 13, 14, and 

15 are installed on the power unit and the adapter 

frame tube.

10 AM

P FUS

E & H

OLDE

R

Protec

ts aga

inst de

ad sho

rts

in this

 "contr

ol circ

uit".

If blow

n, pull 

"fuse h

older

cap", r

eplace

 fuse, r

eplace

"cap". 

If fuse

 contin

ues to

blow, c

ontact 

a quali

fied

mecha

nic, "c

ontrol c

ircuit"

may b

e dam

aged.

FUS

IBL

E D

E 10

 AM

PER

IOS

 Y 

SOP

ORT

E - 

Pro

teg

e co

ntra

 

cort

ocir

cuit

os f

ran

cos

 en

 es

te “

circ

uito

 

de c

ontr

ol”. 

Si e

l fu

sibl

e se

 qu

emó

quit

e la

 “ta

pa d

el s

opo

rte 

del 

fus

ible

”, 

cam

bie 

el fu

sibl

e y 

vue

lva

 a c

oloc

ar la

 

“tap

a”. S

i el

 fus

ible

 co

ntin

úa 

que

mán

dos

e, c

omu

níqu

ese

 co

n un

 

mec

ánic

o ca

lific

ado

, da

do q

ue e

“cir

cuit

o de

 co

ntro

l” p

odr

ía e

star

 da

ñad

o.

 A-

131

001

-C

Welding on galvanized and stainless

steel parts gives off especially

hazardous fumes.

• Remove galvanizing from area to weld.

• Provide good ventilation.

• Wear suitable respirator.

A-131125

This hydraulic reservoir is

filled with Kendall Glacial Blu
hydraulic fluid. Use ONLY the

same or equivalent fluid.

A-131133

A-131028

13

11

12

14

15

Item

Part 

Number

Description

1

A-131115 Warning, Personal Injury

2

ATU-423

Operating Instructions

3

A-150238 Notice - Protected With Electrical Overload Circuit 

Breaker

4

ATU-141

After Using Liftgate

5

A-131061 

A-131062 

A-171433 

A-131120 

A-131119

2500 Lb. Maximum Capacity 

3000 Lb. Maximum Capacity 

4000 lb. Maximum Capacity 

5000 lb. Maximum Capacity 

6000 lb. Maximum Capacity

6*

A-131034 Anthony Label

7*

A-131017 Note - Disengage Latch

8*

A-150601 Made In The USA

10* A-131036

Warning, 200 Amp Fuse Changing Procedure 

(attached only to A-133105 200 AMP Power 

Cable)

11* A-131001 10 Amp Fuse Changing Procedure (attached to 

control wiring in pump box)

12

A-131028 Weld Warning

13* A-131133 Hydraulic Fluid

14* A-131125 Warning, Galvanized Fumes Hazard (galvanized 

models only)

15

A-131106 Warning - Remove Bolts After Installation

*Factory Installed – Installer must make sure all decals are attached, as 

shown.

Summary of Contents for MTU-GLR Series

Page 1: ...Made in the USA MTU GLR MTU GLR WR 3 MTU GLR WR 4 MTU GLR EX 3 MTU GLR EX 4 MTU GLR 25 MTU GLR 3 MTU GLR 4 MTU GLR 5 MTU GLR 6 Quality Reliability Customer Service MTU GLR 3 4 Shown MAINTENANCE MANUAL...

Page 2: ......

Page 3: ...4 2 Semi Annual Inspection 10 4 3 Adjusting Wheel Arm 10 4 4 Platform Adjustment 11 4 5 Replace the Power Cable Fuse 12 4 5 1 Replace the 200 AMP Fuse 12 4 5 2 Replace the 175 AMP Fuse 12 4 6 Checkin...

Page 4: ...ng is installed or changed it must not alter or prevent vehicle compliance with any existing State or Federal standards such as FMVSS 108 Lamps Reflective Devices and Associated Equipment 1 3 2 Rear I...

Page 5: ...ded by being alert and recognizing potentially hazardous situations The safety information in this manual serves as a basic guide in an attempt to prevent injury or death Anthony Liftgates cannot anti...

Page 6: ...ed Actions Do not alter or modify Do not weld No smoking No open flame No alcohol No drugs 2 2 3 Hazard Avoidance Safety alert symbol Slipping injury Tripping injury Pinch point hazard Pinch hazard fo...

Page 7: ...e damaged A cut battery cable can cause sparks and or component damage resulting in loss of vehicle control serious injury or even death CAUTION OEM If replacement parts are necessary genuine factory...

Page 8: ...ess There are no long term health effects Metal fume fever typically begins about four hours after exposure and full recovery occurs within 48 hours 2 4 2 Stainless Steel Follow all OSHA and other wor...

Page 9: ...Port and Breather Cap Reservoir Power Up High Pressure Hose Flow Control Valve Power Down High Pressure Hose Motor Start Solenoid Pump Adjustable Relief Valves Control Box Wiring 10 Amp In Line Fuse...

Page 10: ...ot mix hydraulic oil and automatic transmission fluid due to possible compatibility problems Use the appropriate viscosity of fluid based on the surrounding climate conditions Viscosity is important b...

Page 11: ...4 ALI 00590 1 The platform should lower parallel to the ground until the back portion nearest the truck touches It should then tilt forward until the front edge touches the ground 1 2 ALI 00589 2 To r...

Page 12: ...a is clear 4 5 2 Replace the 175 AMP Fuse CAUTION To avoid injury or property damage disconnect the liftgate s power cable from the battery before starting to replace the fuse An arc can occur resulti...

Page 13: ...Checking Lowering Valve Cartridge and Solenoid 1 Place the liftgate on the ground in the open position 2 Place a steel screwdriver over the top of the lowering valve solenoid ALI 00593 3 Momentarily...

Page 14: ...o the power up port 3 Connect a pressure gauge and reconnect the hydraulic hose The pressure gauge must be rated above the maximum pressure of the liftgate For example use a 4000 psi pressure gauge on...

Page 15: ...eservoir In an emergency use any anti wear hydraulic fluid but flush the system and replace it with our recommended fluid soon as reasonably possible Do not mix hydraulic oil and automatic transmissio...

Page 16: ...is control circuit If blown pull fuse holder cap replace fuse replace cap If fuse continue s to blow contact a qualified mechan ic control circuit may be damage d FUSIBL E DE 10 AMPER IOS Y SOPOR TE P...

Page 17: ...d and store platform Make sure platform is locked in storage position with latch pin after use 6 Manually unfold main platform Always stand on curbside of truck when unfolding platform 3 Manually unfo...

Page 18: ...otects against dead shorts in this control circuit If blown pull fuse holder cap replace fuse replace cap If fuse continues to blow contact a qualified mechanic control circuit may be damaged 12 A 131...

Page 19: ...hexavalent chromium fumes that can irritate the nose throat and lungs Repeated or prolonged exposure can damage the mucous membranes of the nasal passages and result in ulcers In severe cases exposure...

Page 20: ...e Connect motor directly to a spare battery using the procedure in the Maintenance section Motor If the motor is determined to be defective it should be replaced Defective motors are typically caused...

Page 21: ...maged parts Low fluid level Fill reservoir 4 1 Monthly Inspection on page 10 Low Voltage Inspect the battery connection terminals and check the battery s Voltage 9 Volts minimum Faulty lowering valve...

Page 22: ...der operates properly replace the valve 4 13 Checking Flow Control Valve on page 14 Lowering valve Solenoid or cartridge may need cleaning or replacement See Maintenance section 4 8 Checking Lowering...

Page 23: ...NOTES...

Page 24: ...5 PH 815 842 3383 FAX 815 844 3612 TOLL FREE 800 482 0003 WWW ANTHONYLIFTGATES COM THE ORIGINAL NAME IN LIFTGATES SINCE 1941 Gentle Level Ride GLR Our platform maintains a smooth level up and down ope...