3
CONNECTION OF BATTERIES INTO A BATTERY BANK
•
You can connect the Antigravity DC-100-V2 in the Series/Parallel connections as documented below in Fig 1.
• NOTE:
Do not exceed these specifications and make sure only batteries of the same Brand, Amp Hours and
Chemical makeups are used in a Battery Bank. All batteries in a battery bank should be charged to within .02v
of each other before connecting to ensure they will discharge and recharge at the same capacity.
•
In Fig 2 and Fig 3 we demonstrate a typical 2 battery connection in Parallel and Series Connections. If you are
unsure of what this represents please contact a Professional for assistance with your installation.
1 Series (12V)
2 Series (24V)
3 Series (36V)
4 Series (48V)
1 Parallel (100Ah)
YES
YES
YES
YES
2 Parallel (200Ah)
YES
YES
YES
YES
3
Parallel (300Ah)
YES
YES
NO
NO
4
Parallel (400Ah)
YES
YES
NO
NO
Parallel Connection
= 12v with 200 Amp Hours
FIG. 1
FIG. 2
Series Connection
= 24v with 100 Amp Hours