Maintenance
Note: Disconnect the power plug from the electrical outlet
before cleaning.
Cleaning agents:
Never use harsh, abrasive cleaners, heavy-duty clean-
ers or solvents on any surface.
Exterior:
Wipe with damp, sudsy cloth, rinse and dry. For stubborn stains
and periodic waxing, use silicon wax.
Interior:
Wash shelves and other removable parts in warm sudsy water,
rinse and dry. Wash interior with a baking soda solution (3 tablespoons to
liter of water) or warm sudsy water, rinse and dry.
Magnetic door seals:
Wash with warm sudsy water.
Troubleshooting
Symptom
Possible cause
Solution
The drinks cooler does
not start
1.
There is a power
failure
2.
A house fuse has
blown
1.
Ensure the cooler is plugged
in and the power socket
turned on.
2.
Replace the broken fuse in
your meter box
The drinks cooler is
not reaching the set
temperature
1.
The cooler is placed
too close to a heat
source
2.
Insufficient ventilation
3.
The door is opened
too frequently or for a
long period of time
1.
Keep the cooler away from
sunshine or other heat
sources
2.
Place the drinks cooler in
good ventilation and keep
any items away from the
fans
3.
Close the door tightly and
do not open the door too
frequently or for a long
period of time
Undesired noise
1.
Dust in the ventilation
openings
2.
The bottles are touch-
ing each other
3.
Fan defect
4.
Other mechanical
defect
1.
Clean the unit
2.
Adjust the bottles
3.
Contact service
4.
Contact service
Technical data
Model no.
Anton Oliver BCW-25
Anton Oliver BCW-35
Anton Oliver BCW-48
Capacity
Net 21 l
Net 32 l
Net 40 l
Voltage
220~240 V, 50/60 Hz
220~240 V, 50/60 Hz
220~240 V, 50/60 Hz
Effect
65 W
65 W
65 W
Power consumption
100 KWh/annum
121 KWh/annum
209 KWh/annum
Temperature zone
8-18
o
C
10-18
o
C
12-18
o
C
Net weight
9,5 kg
12,3 kg
14 kg
Measurements
252 x 500 x 457 mm
252 x 500 x 635 mm
430 x 485 x 515 mm
Insulation blowing agent
Cyclopentane
Cyclopentane
Cyclopentane
Energy class
A+
A
C
Climate class
N
N
N
Noise level
33 dB
33 dB
33 dB