®
P/N 1011596 Rev. A 05/21
12
Inlet Water Plumbing
Filtered water from a base filtration system
should be connected to the inlet of the RO
System.
Connect Beverage hose (not supplied) to
the outlet of the base filtration system.
Before connecting to the RO System
inlet, the plumbing from the base filtration
system must be flushed clear of all debris.
Hold a bucket at the inlet water line and
slowly open the base filtration water valve.
Allow the plumbing to flush until all debris
is removed.
System Inlet Connection
The System Inlet has a 3/8” OD tube
connection at the Inlet (Figure 9).
Filtered Water Product Outlet
Connection
The System Permeate has a 1/4” OD tube
connection
(Figure 9)
. Use 1/4” OD tubing,
or larger (not supplied) to connect between
the product outlet and the downstream
equipment.
A Tee fitting should be installed in this line
from the system to connect to a tank (not
supplied)(Figure 10).
It is recommended that a shut-off valve be
installed in the line to the tank.
Install Pre-filters and RO
Membrane
If not already installed, install the Pre-filters
and RO Membrane.
The white sediment prefilter must be
installed in the
left
prefilter housing,
closest to the water inlet.
The carbon prefilter must be installed
in the
right
prefilter housing, after the
sediment prefilter.
The RO membrane
must
be installed with
the brine seal on the right, nearest to the
RO membrane housing inlet. It should only
be inserted into the RO housing from the
right side.
1.
Pull out the tube which is inserted
into the RO housing’s inlet (Figure
11a)
2.
Using the supplied wrench,
unscrew the RO housing end cap
and insert the RO membrane into
the housing. The RO membrane
must be installed with the brine
seal on the right side, nearest to
the RO membrane housing inlet. It
should only be inserted into the RO
housing from the right side.
Figure 10.
Recommended Tank Connection
Figure 11. Prefilter and RO Membrane Housings
Base Filter
System
RO
System
To store
Shut-off
Valve
Tank
Figure 9.
Inlet and Outlet Connections
Permeate Inlet
Drain
3.
Reattach the RO membrane
housing end cap.
4.
Insert the tube that was removed in
step 1 into the RO housing inlet.
Sediment
Prefilter
Carbon
Prefilter
RO Membrane
Housing
RO Membrane
Housing End
Cap
Figure 11a