P/N 1011596 Rev. A 05/21
9
UV Installation
(Option on systems 9710141 and
9710142)
NOTE:
The UV must be connected into
the plumbing circle, otherwise
the water will come out of the
system.
WARNING:
The UV light given off by
the UV bulb can cause serious
burns to unprotected eyes
and skin. Do NOT perform any
maintenance tasks with the bulb
plugged in and powered on.
Pay attention to the following guidelines
when working with the UV light:
y
Never look directly at an
illuminated UV lamp
y
Always unplug the UV unit before
performing any work on the UV
bulb or disinfection system
y
Never operate the UV bulb
outside of the UV housing
It is recommended that the UV light be
mounted below the filtration system
horizontally.
The UV light comes with two clips for
mounting and a power supply.
1.
Refer to Figure 4 and 5, mount the
clips beside the filtration system
with the appropriate mounting
hardware.
NOTE:
Pay attention to the distance
between the two clips, it is
recommended that the distance be
approximately 2/3 the length of the
UV light.
2.
Take out the UV bulb and the power
supply from the box.
3.
Insert the bulb into the UV housing.
Only keep the end of the bulb out.
4.
Connect the bulb and the power
supply.
5.
Attach the power supply to the UV
housing.
6.
Place the UV housing onto the clips
properly, refer to Figure 5.
Figure 4.
UV Clip
Figure 5.
UV Unit Mounting
Figure 6.
UV Connection
UV Connection
The UV System must be connected to
the RO system before connecting to inlet
water.
There are two tubes from the filtration
system. Each has a specific label at the
end of each tube. When connecting the
UV, please follow the instructions below:
1.
Connect the tubing to the UV, as
indicated by the attached label.
Each label on the tubing should be
the same label as that on the UV
connection (Figure 6).
2.
Connect to the drinking water port if
needed (OPTIONAL).