background image

P/N 1011306 Rev. D   12/17

2

CONTENTS

General 2
Warranty 
Information 2
Service/Technical  
Assistance 2
Important Safety 
Information 3
Warnings 3
Specifications 4

Dimensions 4
Electrical Ratings 

4

Installation 5

Unpacking 5
Equipment Setup 

5

Operations and Programming 

6

Maintenance 6

Daily Cleaning 

6

Display Codes 

7

Troubleshooting 8
Replacement Parts DCH-500 

9

Replacement Parts DCH-800 

11

Replacement Parts DCH-1000 

13

Notes 15

GENERAL

This manual provides the safety, installation, 

and operating procedures for your toaster. 

Please read all of the information contained 

in this manual prior to installing and operat-

ing the toaster. 

This product is manufactured from the 

finest materials  available and is assembled 

to Roundup’s strict quality standards. This 

toaster was tested at the factory to ensure 

dependable trouble-free operation.

WARRANTY 

INFORMATION

Please read the full text of the Limited 

Warranty in this manual.

If the unit arrives damaged, contact the 

carrier immediately and file a damage claim 

with them. Save all packing materials when 

filing a claim. Freight damage claims are the 

responsibility of the purchaser and are not 

covered under warranty.

The warranty does not extend to:

 

y

Damages caused in shipment or 

damage as result of improper use.

 

y

Installation of electrical service.

 

y

Normal maintenance as 

outlined in this manual.

 

y

Malfunction resulting from 

improper maintenance.

 

y

Damage caused by abuse 

or careless handling.

 

y

Damage from moisture into 

electrical components. 

 

y

Damage from tampering with, 

removal of, or changing any 

preset control or safety device.

SERVICE/TECHNICAL  

ASSISTANCE

If you experience any problems with the 

installation or operation of your system, 

contact Antunes  at 1-630-784-1000, or toll 

free in the United States at 1-800-253-2991.

Fill in the information in the next col-

umn and have it handy when calling for 

assistance. The serial number is on the 

specification plate located on the system.

Purchased From

Date of Purchase

Model Number

Serial Number

Mfg. Number

Use only genuine Antunes replacement 

parts in this unit. Use of replacement parts 

other than those supplied by the manufac-

turer will void the warranty. Your Authorized 

Service Agency has been factory trained 

and has a complete supply of parts for this 

unit.

IMPORTANT

A.J. Antunes & Co. reserves the right to 

change specifications and product de-

sign without notice. Such revisions do not 

entitle the buyer to corresponding changes, 

improvements, additions or replacements 

for previously purchased equipment.

IMPORTANT

Keep these instructions for future refer-

ence. If the unit changes ownership, be sure 

this manual accompanies the equipment.

Summary of Contents for DCH-1000

Page 1: ...P N 1011306 Rev D 12 17 Heated Display Cabinet owner s manual Models DCH 500 DCH 800 DCH 1000 Manufacturing Numbers 9500640 9500650 9500720 www antunes com ...

Page 2: ...r damage as result of improper use y y Installation of electrical service y y Normal maintenance as outlined in this manual y y Malfunction resulting from improper maintenance y y Damage caused by abuse or careless handling y y Damage from moisture into electrical components y y Damage from tampering with removal of or changing any preset control or safety device SERVICE TECHNICAL ASSISTANCE If yo...

Page 3: ...rating and performing maintenance on this unit y y If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard y y Do not modify the power supply cord plug If it does not fit the outlet have a proper outlet installed by a qualified electrician y y Do not use an extension cord with this appliance y y Electrica...

Page 4: ...6 50 60 NEMA 5 15P 15 Amp 120 Volt DCH 800 9500650 120 800 6 6 50 60 DCH 1000 9500640 120 1000 8 3 50 60 Electrical Ratings Dimensions Model Mfg No A Height B Width C Depth DCH 500 9500720 28 711 mm 23 75 603 25 mm 25 635 mm DCH 800 9500650 28 711 mm 37 75 958 8 mm 25 635 mm DCH 1000 9500640 28 711 mm 47 75 1212 8 mm 25 635 mm ...

Page 5: ...rface Ensure that the line voltage corresponds to the stated voltage on the unit specification label Ensure the power to the unit is turned off before plugging in the power cord CAUTION All electrical connections must be in accordance with local electrical codes and any other applicable codes WARNING y y ELECTRICAL SHOCK HAZARD Failure to follow the instructions in this manual could result in seri...

Page 6: ...ter Then rinse and wipe dry 4 Clean glass surfaces inside and out with an approved glass cleaner 5 Wipe all non glass surfaces of the unit with a clean damp towel and allow to air dry OPERATIONS AND PROGRAMMING The DCH 800 andDCH 1000 is designed to temporarily slow the cooling of food NOTE This unit has an adjustable temperature range of 150 165 F 66 74 C NOTE The Setpoint temperature is the desi...

Page 7: ... exceeds the setpoint temperature or if the thermistor has shorted NOTE The thermistor should be 100k ohm 2 at room temperature OPEN flashes if the thermistor is OPEN or disconnected The unit will not call for heat NOTE The thermistor should be 100k ohms 2 at room temperature PO In 120 VAC units this code flashes if the supply voltage is below 100 VAC or above 135 VAC In 220 240 VAC units this cod...

Page 8: ...e Relay Contact your maintenance person or Authorized Service Agency for service Inoperable Control Board Inoperable Heater s Loose burnt broken wiring in circuit Display flashes HI and the cabinet does not heat up Inoperable Thermistor Contact your maintenance person or Authorized Service Agency for service Inoperable control Board Display flashes HI and the cabinet is very hot Solid State Relay ...

Page 9: ... 0900320 Front Glass 1 4 5040282 Rail 48 68 LG 1 5 7001732 Glass Shelf Kit 24 1 6 7001380 Side Glass Kit 0900319 2 7 2000253 Glass Shelf Mounting Hdwe 2 8 7001435 Glass Shelf Support Kit 2 9 7001438 Corner Bracket 2 10 215P410 Spacer 1 11 325P207 Washer 1 12 210P360 Thumb Screw 1 13 215P152 Nylon Push in Bearing 1 Available in packages of ten ...

Page 10: ...ermostat Hi Limit Kit 1 15 7001478 Terminal Block Kit 1 16 0013258 Control Panel Assembly 1 Item Part No Description Qty 17 0022270 Heat SinkWeldment 1 20 7001148 Transformer 120VAC 12VAC 1 21 7000370 Solid State Relay Kit 1 22 0400251 Strain Relief 1 23 0700463 Power Cord 1 24 7001718 Power Supply Kit 1 25 308P203 Screw 8 32 X 3 8With Int ToothWasher 1 26 308P199 Nut Hex Keps 8 32 S S Cti Ifn0037...

Page 11: ...ion Qty 1 7001714 Top Glass Kit 36 1 3 0900326 Front Glass Assy 1 4 5040284 36 Frame Hinge 1 5 Middle Shelf waiting on kit 1 6 7001380 Side Glass Kit 0900319 2 7 7001435 Glass Shelf Support Kit 2 9 7001438 Corner Bracket 2 10 215P410 Spacer 1 11 325P207 Washer 1 12 210P360 Thumb Screw 1 13 215P152 Nylon Push in Bearing 1 Available in packages of ten ...

Page 12: ...Limit Kit 1 15 7001478 Terminal Block Kit 1 Item Part No Description Qty 16 7000345 Control Board Kit 1 17 0022132 Heat Sink BracketWeldment 1 20 7001148 Transformer 120VAC 12VAC 1 21 7000370 Solid State Relay Kit 1 22 0400251 Strain Relief 1 23 0700463 Power Cord 1 24 7001718 Power Supply Kit 1 25 308P203 Screw 8 32 X 3 8With Int ToothWasher 1 26 308P199 Nut Hex Keps 8 32 S S Cti Ifn00374 1 27 00...

Page 13: ...1 2 7001869 Front Glass kit 1 3 0900320 Front Glass 1 4 5040282 Rail 48 68 LG 1 5 7001870 Glass Shelf Kit 1 6 7001380 Side Glass Kit 0900319 2 7 7001435 Glass Shelf Support Kit 2 8 7001438 Corner Bracket 2 9 210P360 Thumb Screw 1 REPLACEMENT PARTS DCH 1000 SHEET 1 3 2 4 1 5 8 7 4 6 9 ...

Page 14: ...l Board Kit 1 Item Part No Description Qty 17 0022132 Heat SinkWeldment 1 20 7001148 Transformer 120VAC 12VAC 1 21 7000370 Solid State Relay Kit 1 22 0400251 Strain Relief 1 23 0700463 Power Cord 1 24 7001718 Power Supply Kit 1 25 308P203 Screw 8 32 X 3 8With Int ToothWasher 1 26 308P199 Nut Hex Keps 8 32 S S Cti Ifn00374 1 27 0022097 Control PanelWeldment 1 28 0400138 Nut Lock Conduit 1 2 1 29 05...

Page 15: ...P N 1011306 Rev D 12 17 15 NOTES ...

Page 16: ...P N 1011306 Rev D 12 17 16 ...

Page 17: ...warranty does not cover water contamination problems such as foreign material in water lines or inside solenoid valves It does not cover water pressure problems or failures resulting from improper incorrect voltage supply This warranty does not cover Travel Time Mileage in excess of 2 hours 100 miles 160 km round trip from the nearest authorized service agency 2 Roundup reserves the right to make ...

Reviews: