6
P/N 1012011 Rev. C 06/18
User Mode
User Mode allows an operator to
view the toaster settings but does
not permit any adjustments.
1. Press and hold the
PROGRAM
button for 5 seconds. After 5
seconds, the display will show
the actual temperature of the
Platen.
2. Press the
LIGHTER
button to
toggle between the Setpoint and
actual temperature of the Platen
Heater.
3. Press the
PROGRAM
button to
proceed to the Motor Menu. The
display shows the actual speed
of the motor.
4. Press the
LIGHTER
button to
toggle between the Setpoint and
actual speed of the Motor.
NOTICE:
The unit will exit User
Mode after 5 seconds of
keypad inactivity.
Error Codes
If any of the following Error Codes
appear, press and release the Power
button to turn the toaster off. Al
-
low the unit to cool. Then press and
release the Power button to turn the
toaster on. If the error repeats, contact
Antunes Technical Service for assis-
tance.
NOTICE:
ERR #1, 2 , 3, 5, 6, 7, and
30 to 51: Internal Error. Cycle
the power. If error persists,
replace the board.
Error
Description
ERR
8
Motor running when it
should be off.
ERR
9
High Internal Temperature.
ERR
10
Shorted Thermocouple.
ERR
11
Open Thermocouple.
Manager Mode
Manager Mode allows an opera-
tor to view and adjust the following
settings:
y
Heater Temperature
y
Motor Speed
y
Temperature Units
(Celsius or Fahrenheit)
Manager Mode also allows an
operator to view (but not adjust) the
Ambient Temperature of the Control
Compartment.
1. Press and release the Power
button to turn the toaster off.
2. Press and release the Power
button while holding the
PRO-
GRAM
button. Continue holding
the button until “ENA” appears
on the display (after approxi
-
mately 10 seconds).
3. Release the
PROGRAM
button.
The display shows the Heater
Setpoint Temperature.
4. To adjust the Heater Setpoint
Temperature, press the
LIGHT-
ER
or
DARKER
buttons to
reach the desired temperature.
NOTICE:
The recommended
temperature setting for the
Platen is 545 °F (285 °C).dd
5. Press the
PROGRAM
button to
procedure to the Motor Speed
Setpoint.
6. Adjust the Motor Speed Setpoint
by pressing the
LIGHTER
or
DARKER
buttons to reach the
desired speed.
NOTICE:
The Motor Speed is
adjustable from 1-100. The
recommended setting is 57.
7. Press the
PROGRAM
button
to proceed to the Temperature
Units.
8. To change the Temperatures
units from Fahrenheit or Cel
-
sius, press the
LIGHTER
or
DARKER
buttons.
9. Press and hold the
PROGRAM
button to save any changes.
NOTICE:
The unit exits Manager
Mode after 30 seconds of
keypad inactivity.
Safety Features
Hi-Limit Control
A Hi-Limit Control turns off electri
-
cal power to the heaters and control
circuits and displays HL if the unit
overheats. To reset the control:
1. Let the unit cool for 15 minutes.
2. Locate the Hi-Limit Controls on
the rear of the unit. Remove the
black protective cap.
3. Press and release the button.
Re-install the protective cap.
NOTICE:
If the Hi-Limit Control
requires continuous reset-
ting, contact your Authorized
Service Agency.
Purging Buns from Toaster
If buns get stuck in the toaster,
press and hold both the
UP
and
DOWN
arrow buttons to increase
the belt speed until the buns are
purged from the toaster.
Fault Messages
The unit displays fault messages
when there is a problem with the
unit.
y
“
Hi
” flashes if the Platen
Heater temperature is 30
°F
more than the Setpoint or
if the Platen Thermocouple
is disconnected or open.
y
“
CHEC
” flashes when the
control compartment ambient
temperature is more than 150
°F (66
°C). All heaters shut
off. The unit will not restart
until the control compartment
ambient temperature falls
below 140
°F (60
°C).
y
“
PO
” flashes if the incoming
power drops below 190 volts.
The toaster shuts down.
y
“
StoP
” flashes when the
motor has stopped for seven
continuous seconds.
y
“
SpEd
” flashes when the
motor speed drops 25%
below the Setpoint for 30
continuous seconds.
y
“
PLt
” slow warmup (2:20 Min)
y
“
SSr
” The Solid State Relay
has shorted - the unit is running