background image

6

P/N 1012011 Rev. C 06/18

User Mode

User Mode allows an operator to 

view the toaster settings but does 

not permit any adjustments.
1.  Press and hold the 

PROGRAM

 

button for 5 seconds. After 5 

seconds, the display will show 

the actual temperature of the 

Platen.

2.  Press the 

LIGHTER

 button to 

toggle between the Setpoint and 

actual temperature of the Platen 

Heater.

3.  Press the 

PROGRAM

 button to 

proceed to the Motor Menu. The 

display shows the actual speed 

of the motor.

4.  Press the 

LIGHTER

 button to 

toggle between the Setpoint and 

actual speed of the Motor.

NOTICE:

 The unit will exit User 

Mode after 5 seconds of 

keypad inactivity.

Error Codes

If any of the following Error Codes 

appear, press and release the Power 

button to turn the toaster off. Al

-

low the unit to cool. Then press and 

release the Power button to turn the 

toaster on. If the error repeats, contact 

Antunes Technical Service for assis-

tance.

NOTICE:

 ERR #1, 2 , 3, 5, 6, 7, and 

30 to 51: Internal Error. Cycle 

the power. If error persists, 

replace the board.

Error

Description

ERR 

8

Motor running when it 

should be off.

ERR 

9

High Internal Temperature.

ERR 

10

Shorted Thermocouple.

ERR 

11

Open Thermocouple.

Manager Mode

Manager Mode allows an opera-

tor to view and adjust the following 

settings:

 

y

Heater Temperature

 

y

Motor Speed

 

y

Temperature Units  

(Celsius or Fahrenheit)

Manager Mode also allows an 

operator to view (but not adjust) the 

Ambient Temperature of the Control 

Compartment.
1.  Press and release the Power 

button to turn the toaster off.

2.  Press and release the Power 

button while holding the 

PRO-

GRAM

 button. Continue holding 

the button until “ENA” appears 

on the display (after approxi

-

mately 10 seconds).

3.  Release the 

PROGRAM

 button. 

The display shows the Heater 

Setpoint Temperature. 

4.  To adjust the Heater Setpoint 

Temperature, press the 

LIGHT-

ER

 or 

DARKER

 buttons to 

reach the desired temperature.

NOTICE:

 The recommended 

temperature setting for the 

Platen is 545 °F (285 °C).dd

5.  Press the 

PROGRAM

 button to 

procedure to the Motor Speed 

Setpoint.

6.  Adjust the Motor Speed Setpoint 

by pressing the 

LIGHTER

 or 

DARKER

 buttons to reach the 

desired speed.

NOTICE:

 The Motor Speed is 

adjustable from 1-100. The 

recommended setting is 57.

7.  Press the 

PROGRAM

 button 

to proceed to the Temperature 

Units. 

8.  To change the Temperatures 

units from Fahrenheit or Cel

-

sius, press the 

LIGHTER

 or 

DARKER

 buttons.

9.  Press and hold the 

PROGRAM

 

button to save any changes.

NOTICE:

 The unit exits Manager 

Mode after 30 seconds of 

keypad inactivity.

Safety Features

Hi-Limit Control

A Hi-Limit Control turns off electri

-

cal power to the heaters and control 

circuits and displays HL if the unit 

overheats. To reset the control:
1.  Let the unit cool for 15 minutes.
2.  Locate the Hi-Limit Controls on 

the rear of the unit. Remove the 

black protective cap.

3.  Press and release the button. 

Re-install the protective cap.

NOTICE:

 If the Hi-Limit Control 

requires continuous reset-

ting, contact your Authorized 

Service Agency.

Purging Buns from Toaster

If buns get stuck in the toaster, 

press and hold both the 

UP

 and 

DOWN

 arrow buttons to increase 

the belt speed until the buns are 

purged from the toaster. 

Fault Messages

The unit displays fault messages 

when there is a problem with the 

unit.

 

y

Hi

” flashes if the Platen 

Heater temperature is 30

 

°F 

more than the Setpoint or 

if the Platen Thermocouple 

is disconnected or open.

 

y

CHEC

” flashes when the 

control compartment ambient 

temperature is more than 150

 

°F (66

 

°C). All heaters shut 

off. The unit will not restart 

until the control compartment 

ambient temperature falls 

below 140

 

°F (60

 

°C).

 

y

PO

” flashes if the incoming 

power drops below 190 volts. 

The toaster shuts down.

 

y

StoP

” flashes when the 

motor has stopped for seven 

continuous seconds. 

 

y

SpEd

” flashes when the 

motor speed drops 25% 

below the Setpoint for 30 

continuous seconds.

 

y

PLt

” slow warmup (2:20 Min)

 

y

SSr

” The Solid State Relay 

has shorted - the unit is running 

beyond the setpoint temperature.

Summary of Contents for Gold Standard Toaster GST-2H

Page 1: ...P N 11012011 Rev C 06 18 Gold Standard Toaster owner s manual Model GST 2H Int l Manufacturing Numbers 9210961 9210962 www antunes com ...

Page 2: ...ontact Antunes Customer Service immediately at 1 877 392 7856 toll free If there are problems with the installation or operation of this product contact Antunes Technical Service toll free at 1 877 392 7854 Fill in the information in the next column and have it handy when calling for assistance The serial number is on the specification plate located on the system Equipment Information to Save Purc...

Page 3: ...ng over the edge of a table or counter Maintenance y y Do not use abrasive materials they can damage the toaster s stainless steel finish y y Do not use corrosive chemicals in this equipment y y Chlorides or phosphates in cleaning agents e g bleach sanitizers degreasers and detergents can permanently damage stainless steel equipment The damage is usually in the form of discoloration dulling of the...

Page 4: ...Description GST 2H 9210961 230 2000 50 60 CEE 7 7 16 Amp 250 VAC Assembly Only GST 2H 9210962 208 2000 60 NEMA 6 20P 20 Amp 250 Volt Right Angle A B C Model Mfg No Width A Depth B Height C GST 2H 9210961 22 559 mm 21 533 mm 17 432 mm GST 2H 9210962 22 559 mm 21 533 mm 17 432 mm ...

Page 5: ...nter y y Place the unit on a sturdy level table or other work surface y y Turn the power switch to off if it is set to on y y Ensure the line voltage corresponds to the stated voltage on the specification label and power cord warning tag 8 Plug the power cord into the ap propriate power outlet Refer to the specification plate for the proper voltage Figure 1 Gold Standard Toaster 2H Operation 1 Pre...

Page 6: ...CE The recommended temperature setting for the Platen is 545 F 285 C dd 5 Press the PROGRAM button to procedure to the Motor Speed Setpoint 6 Adjust the Motor Speed Setpoint by pressing the LIGHTER or DARKER buttons to reach the desired speed NOTICE The Motor Speed is adjustable from 1 100 The recommended setting is 57 7 Press the PROGRAM button to proceed to the Temperature Units 8 To change the ...

Page 7: ...Y QSR Heat Activated Grill Toaster Cleaner on a non abrasive pad 2 Wash step Wipe with the non abrasive pad damped with the Grill Toaster Cleaner 3 Rinse step Wipe with a clean towel dampened with water 4 Sanitize step Wipe with a clean towel soaked in KAYQUAT II Sanitizer solution and allow to air dry 5 Clean the top and bottom belts each belt should follow the Wash Rinse Sanitize step NOTICE Rep...

Page 8: ...d the backing plates so they are as clean as possible 10 Use a dry cloth towel or nylon bristled brush to remove all debris from both side compart ments inside of the toaster and underneath the rollers Install Belt Wraps 1 If you are installing the existing belt wraps inspect the belts Replace belt wraps if worn or damaged If the belt wraps are in good condition put them back on the toaster 2 For ...

Page 9: ...remove the left side cover of the unit by lifting up and away from the unit Set aside Figure 7 Accessing the cooling fan 3 Remove any debris or dust from the cooling fan with a small brush Wipe away any debris with a clean dry towel Inspect the electrical compartment for crumbs and debris Clean out all crumbs and debris using a clean dry towel or nylon bristled brush Be careful not to disrupt any ...

Page 10: ...mocouple for continuity Contact your maintenance person or Antunes Technical Service for service Failed Control Board Control Display flashes Er 10 continuously Buns not toasting properly Shorted Platen Thermocouple to ground Disconnect and re secure the Platen Thermocou ple connection to the Control Board If the Control Display still reads Er 10 check the Thermocouple for continuity Contact your ...

Page 11: ...Service for service Cooling Fan is dirty and needs to be cleaned Control Display flashes HL continuously Buns are not toasting properly Hi Limit Control is tripped Allow the unit to cool and reset the Hi Limit Con trol If it trips again contact your maintenance person or Antunes Technical Service for service Control Display is blank Power Cord is not plugged in Plug the Power Cord into the appropr...

Page 12: ...961 1 0013249 Housing Door Assy Mfg No 9210962 1 12 0013111 Assy Drive Chain Tensioner 1 13 0021724 Weldment Brg Brkt Spring Guide RH 2 14 0021725 Wldmnt Bearing Brkt Spring Guide LH 2 15 0021865 Main Platen Frame Wldmt 1 Item No Part Description Qty 16 0021885 End Housing Weldment 1 17 0021897 End Housing Panel Wldmt 1 18 0021940 Base Weldment 1 19 0021953 Weldment Drive Roller Adjust Lanes 1 20 ...

Page 13: ... 38 82 30 89 65 83 65 43 66 7 88 41 95 71 17 78 57 54 59 76 76 71 104 70 52 50 83 101 72 15 102 77 96 77 53 105 46 27 9 8 44 44 60 35 100 60 35 67 67 4 4 82 4 9 67 38 82 94 30 89 65 83 65 43 66 7 88 41 95 71 17 78 57 54 59 98 76 76 71 104 70 52 50 83 110 112 111 76 NOTICE See Next Page for Parts List related to this graphic NOTICE Use only genuine Antunes replacement parts in this egg station Use ...

Page 14: ... Shock Hazard 1 53 1001505 Label Control 1 54 1001585 Label Compression LH 1 55 1001586 Label Compression RH 1 Item No Part Description Qty 56 1001643 Label Wiring Diagram Mfg No 9210961 1 1001589 Label Wiring Diagram Mfg No 9210962 1 57 2100212 Handle Pocket Pull Snap In 2 59 2100253 Knob 1 4 Shaft Push on 2 60 2100334 Thrust Strip 4 61 2100197 Clip Steel Cable 1 62 2120233 Spacer 252 ID X 5 OD X...

Page 15: ... Heel Plate Wldmt 1 11 0100298 Platen Main 230V 1900W Mfg No 9210961 only 1 0100290 Platen Main 208V 1900W Mfg No 9210962 only 12 0400458 Insulation Main Platen 1 Item No Part Description Qty 13 0506853 Frame Cover 1 14 0507092 Insulation Plate 1 15 0507140 Alum Washer 2 16 0600162 Spring Cam 8 17 2120233 Spacer 252 Id X 5 Od X 925 Lg 4 18 2150362 Cam Hbcs 4 19 2150376 Shaft Crown 1 20 3080144 Scr...

Page 16: ...16 P N 1012011 Rev C 06 18 Wiring Diagram Mfg No 9210961 ...

Page 17: ...17 P N 1012011 Rev C 06 18 Wiring Diagram Mfg No 9210962 ...

Page 18: ...18 P N 1012011 Rev C 06 18 Notes ...

Page 19: ...s 160 km round trip from the nearest authorized service agency Antunes reserves the right to make changes in design or add any improvements on any product The right is always reserved to modify equipment because of factors beyond our control and government regulations Changes to update equipment do not constitute a warranty charge If shipment is damaged in transit the purchaser should make a claim...

Reviews: