Problem
Possible Cause
Corrective Action
Control Display is blank.
Power Cord is not plugged in.
Plug the Power Cord into the appropriate outlet. Turn the toaster
on. If the Control Display is still blank, contact your maintenance
person or Antunes Technical Service for service.
Circuit Breakers turned off or tripped. Damaged
electrical outlet, plug, or Power Cord. Power
Switch damaged.
Reset Circuit Breakers. If they trip again, check the Power Cord,
Plug, and outlet for damage. Contact your maintenance person,
Antunes Technical Service, and Electrician for service.
Faulty Transformer.
Replace Transformer.
Conveyors not turning.
Belt is damaged.
Replace Belts
Motor Drive Chain is detached from sprockets.
Reinstall the Drive Chain.
Failed Drive Motor.
Contact your maintenance person or Antunes Technical Service for
service.
Belts are ripped or torn.
Rollers or Heater Cover Plates are dirty and need
to be cleaned.
Clean Rollers and Heater Cover Plates as outlined in the Mainte-
nance section of this manual.
Belts are not installed properly.
Install Belts correctly as outlined in the Maintenance section of this
manual.
Roller(s) in the incorrect locked position during
operation.
Unlock Rollers to operational position.
Front Conveyor Lock is disengaged.
Engage and lock the Front Conveyor Lock.