MUFFIN TOASTER MT-12
10
P/N 1010918 11/05
TROUBLESHOOTING (continued)
Problem
Possible Cause
Corrective Action
Toaster fails to operate (no
heat, fan not running).
No Power
Make sure plug is locked into position
and the Rocker Switch is ON. Check
building circuit breaker.
Defective receptacle or power cord plug
Plug into different receptacle
Replace cord.
Loose wire connections.
Check and tighten all connections.
Not heating. Fan is working
Hi-Limit thermostat is tripped or defec-
tive.
Turn toaster off for 20-30 minutes and
then press the reset button.
Replace Hi-Limit thermostat.
Removable Plate is scuffed or scratched. Replace Removable Plate.
Removable Plate is too dull or carboned
up.
Clean or replace Removable Plate.
Muffins too light or too dark at
Audio Signal.
Using refrigerated or frozen muffins.
Muffins must be at room temperature
before toasting. Allow a two day old
rotation when using fresh muffins.
Incorrect setting or regional preference
dictates an adjustments of the timer.
Approximate times are:
Partial Load - 85-125 seconds
Full Load - 90-130 seconds
Adjust full or partial load timers as
needed. Refer to the Maintenance sec-
tion of this manual.
Toaster does not operate
properly when it is initially
installed.
Toaster selected/shipped is not for the
electrical service as this location.
Check toaster identification plate and
refer to the Electrical Specifications of
this Manual.
Toaster does not operate
after the replacement of a
Control Board.
One or more electrical service dip
switches are improperly set for the loca-
tions electrical service.
Refer to the Dip Switch setting instruc-
tions provided in this manual.
Toaster will not operate (no
heat and no fan operation)
LED light on and Rocker
Switch not lit.
Rocker Switch (Power On/Off) not On
Confirm that the Rocker Switch is ON.
No Power. Circuit Breaker is off or
tripped.
Reset Circuit Breaker. Contact your
maintenance person or Authorized
Service Agency if it trips again.
Rocker Switch is inoperable.
Replace Rocker Switch.
Poor plug to receptacle connection.
Lock plug into receptacle.
Damaged or defective power cord.
Inspect power cord, replace if needed.
Damaged or defected cord, plug, and/or
pins.
Inspect plug and pins. Replace if
needed.
Damaged or defective receptacle.
Inspect receptacle. Call your electrician.
Loose electrical connection.
Contact your maintenance person or
Authorized Service Agency for service.