Homeowner Do's and Don'ts

To ensure optimum performance of the Puraflo peat fiber biofilter system, the following Do’s and
Do Not’s should be followed: 

Don’t:

Dig in your drainfield or build anything
permanent over it 

Plant anything over your drainfield except

grass 

Drive over your drainfield or compact the

soil in any way 

Attempt any homeowner maintenance to

the septic tank, pump tank, electrical
controls or treatment modules – do not
remove caps or covers as potentially 
hazardous gases and waste matter are
contained in the treatment tanks which
may result in death or bodily injury

Place heavy objects on or drive across your

treatment system 

Bury or cover the modules with soil as the

Puraflo treatment is an aerobic process
that requires free passage of air through
the module lids 

Do:

Maintain a stabilized/grassed landscaped

area around the modules in order to prevent
soil erosion (plants and suitable shrubs can
also be used to enhance the appearance of
the system) 

Keep ant nests and other pests out of the

treatment modules by dosing externally
with suitable insecticides and pest controls
as necessary 

Divert down spouts and other surface

water away from the system and drainfield

Keep your septic tank cover accessible for

tank inspections and pumping 

Have your septic tank pumped regularly

and checked for leaks and cracks 

Have the effluent filter cleaned annually 

Test the pump alarm occasionally 

(as applicable) by briefly activating the
test switch on the alarm 

In the event of the alarm sounding after

electrical storms or power failure, check if
the electrical circuit-breakers tripped off
by first turning them off and then turning
them back on again 

Call your Authorized Service Provider when

you have problems 

Anua_Pflo_OwnerManual_100514_Anua_Pflo_OwnerManual_100514  10/29/14  4:32 PM  Page 3

Summary of Contents for Puraflo

Page 1: ...raflo Peat Fiber Biofilter Owner s Manual Only modules bearing the NSF logo and designated P150N XX are certified to NSF ANSI Standard 40 Call 336 547 9338 or visit anuainternational com 2014 Anua 10 2014 ...

Page 2: ...ump Alarm 7 5 3 Electrical Control Panel 7 5 4 Puraflo Modules 8 6 0 Vacation Seasonal and Intermittent Use 12 7 0 Homeowner Troubleshooting Checklist 13 8 0 Service Agreement 13 8 1 Initial Service Agreement 7 8 2 Extended Service Agreement 7 9 0 Emergency Contact Details 14 9 1 Manufacturer Contact Information 14 9 2 Authorized Service Provider Contact Information 14 10 0 Limited Warranty 14 Cal...

Page 3: ...inlet manifold which allows the flows to be split equally and fed simultaneously to each biofilter module The inlet manifold is connected to the base of the biofilter module and is fed upwards to a rectangular distribution grid located 6 inches below the top of lid The effluent percolates laterally and vertically through the depth of the peat fiber treatment media and emerges as a clear innocuous ...

Page 4: ...rm water drains should not be connected to the septic tank and landscaping should divert storm water away from the modules Use additives septic tank additives should not be introduced into the septic tank for grease reduction stimulation of biological activity or other purposes Dispose of large quantities of organic mate rial through a garbage grinder as this may organically overload the system an...

Page 5: ...aerobic process that requires free passage of air through the module lids Do Maintain a stabilized grassed landscaped area around the modules in order to prevent soil erosion plants and suitable shrubs can also be used to enhance the appearance of the system Keep ant nests and other pests out of the treatment modules by dosing externally with suitable insecticides and pest controls as necessary Di...

Page 6: ...Depending on use a typical home will produce sufficient sludge requiring the septic tank to be pumped every 2 to 10 years The importance of desludging can not be over emphasized since the Puraflo system is designed to treat effluent from a well functioning septic tank where a significant portion of insoluble solids have been allowed to settle out The effluent filter installed with the Puraflo syst...

Page 7: ...o system will function normally when used in vacation seasonal or intermittent homes During normal operation of the Puraflo peat fiber biofilter a stable ecosystem exists in the peat fiber media consisting of a diverse population of microorganisms and also higher life forms During a period of reduced waste waterflowtothePuraflomodules themicrobial population correspondingly decreases in the media ...

Page 8: ...faulty electrical system or pump is faulty 1 High water usage above design capacity activates the alarm float switch 2 Leaking plumbing fixtures 3 Leaking pump or septic tank 4 Broken timer or incorrect timer settings 5 Latched alarm 1 Pump and alarm failure due to circuit breaker switches being tripped to the off position by an electrical storm power surge or power failure 2 Pump and alarm fail c...

Page 9: ... meters Peat modules for any structural damage accessibility adequate ventilation excess odors insect or other pest infestations Vegetative growth over the drainfield Drainfield area for surfacing of the effluent Sample of peat biofilter effluent collected form the sampling point to check for efflu ent clarity and odor note peat biofilter effluent may have a brackish to straw color from the humic ...

Page 10: ...owner shall be notified in writing of improper system operations that cannot be corrected at the time of inspection Upon expiration of this policy our firm will offer a continuing service policy on a yearly basis to cover labor and for normal maintenance and repairs on a year by year basis Violations of warran ty include shutting off electric current to the system for more than 24 hours disconnect...

Page 11: ...ion Name Anua Environmental Products U S Inc Address PO Box 77457 Greensboro North Carolina 27417 Office Phone 336 547 9338 Toll Free Phone 1 800 PURAFLO Fax 336 547 8559 Email Address info anua us com Website Address www anua us com 9 2 Authorized Service Provider Contact Information To identify the initial service provider for your system check the labels on the control panel and fill in the tab...

Page 12: ...ndustry information Such recommendations do not constitute a warranty of satisfactory performance This LIMITED WARRANTY extends to the original retail customer of the product As herein original retail customer is defined as the purchaser who first has the plant installed or in the case of a system designed for non permanent installation the purchaser who first uses the system It is the purchaser s...

Page 13: ...ler name phone ______________________________ ______________________________ ______________________________ Service provider name phone Regulatory Authority Permit if applicable ___________________________________________________________________________________________________ ___________________________________________________________________________________________________ Notice of Transfer I t...

Reviews: