7.0   

Troubleshooting Checklist

Experience slow-flush but electrical

system is operational

Alarm sounds continuously and effluent

level rises steadily in the pump tank –

this can eventually lead to slow-flush

caused by sewage backing up and

could eventually cause effluent to

pond at the septic or pump tank

Alarm sounds periodically but resets

itself (indicating that the pump is still

operating)

Note: Some states require alarms that

are latched (continue to alarm after the

alarm event has been corrected) and

will not auto-reset themselves in which

case it will be necessary to reset the

alarm manually

No alarm warning – effluent level rises

continuously in the pump tank potentially

leading to slow-flush and/or effluent

ponding around septic or pump tank

Ponding of effluent on peat fiber media

1. Unacceptable level of solids in septic tank

2. Effluent filter blocked

1. Pump failure due to circuit breaker

switch being tripped to the “off” position

by an electrical storm or power surge

2. Pump fails due to faulty electrical

system or pump is faulty

1. High water usage above design 

capacity activates the alarm float switch

2. Leaking plumbing fixtures

3. Leaking pump or septic tank

4. Broken timer or incorrect timer settings

5. Latched alarm

1. Pump and alarm failure due to circuit

breaker switches being tripped to the

“off” position by an electrical storm,

power surge or power failure

2. Pump and alarm fail concurrently due

to faulty system electronics

1. Failed drainfield

2. Media at end of useful life

Detection

Possible Cause

Action

1. Pump out septic tank and clean

effluent filter

2. Clean effluent filter

1. Conserve water usage, reset circuit

breaker and test the alarm – if the

problem recurs call your Authorized

Service Provider

2. Conserve water usage and call your

Authorized Service Provider

1. Reduce water usage to range within

the design capacity

2. Repair leaking plumbing fixtures

3. Repair leaks in septic or pump tank

4. Conserve water usage and call your

Authorized Service Provider

5. Reset manually

1. Reset circuit breaker and test the

alarm – if the problem recurs call your

Authorized Service Provider

2. Conserve water usage and call your

Authorized Service Provider

1. Consult with your Authorized Service

Provider

2. Replace peat fiber media and dispose

of spent peat media per local regulations

Anua_Pflo_OwnerManual_100514_Anua_Pflo_OwnerManual_100514  10/29/14  4:32 PM  Page 6

Summary of Contents for Puraflo

Page 1: ...raflo Peat Fiber Biofilter Owner s Manual Only modules bearing the NSF logo and designated P150N XX are certified to NSF ANSI Standard 40 Call 336 547 9338 or visit anuainternational com 2014 Anua 10 2014 ...

Page 2: ...ump Alarm 7 5 3 Electrical Control Panel 7 5 4 Puraflo Modules 8 6 0 Vacation Seasonal and Intermittent Use 12 7 0 Homeowner Troubleshooting Checklist 13 8 0 Service Agreement 13 8 1 Initial Service Agreement 7 8 2 Extended Service Agreement 7 9 0 Emergency Contact Details 14 9 1 Manufacturer Contact Information 14 9 2 Authorized Service Provider Contact Information 14 10 0 Limited Warranty 14 Cal...

Page 3: ...inlet manifold which allows the flows to be split equally and fed simultaneously to each biofilter module The inlet manifold is connected to the base of the biofilter module and is fed upwards to a rectangular distribution grid located 6 inches below the top of lid The effluent percolates laterally and vertically through the depth of the peat fiber treatment media and emerges as a clear innocuous ...

Page 4: ...rm water drains should not be connected to the septic tank and landscaping should divert storm water away from the modules Use additives septic tank additives should not be introduced into the septic tank for grease reduction stimulation of biological activity or other purposes Dispose of large quantities of organic mate rial through a garbage grinder as this may organically overload the system an...

Page 5: ...aerobic process that requires free passage of air through the module lids Do Maintain a stabilized grassed landscaped area around the modules in order to prevent soil erosion plants and suitable shrubs can also be used to enhance the appearance of the system Keep ant nests and other pests out of the treatment modules by dosing externally with suitable insecticides and pest controls as necessary Di...

Page 6: ...Depending on use a typical home will produce sufficient sludge requiring the septic tank to be pumped every 2 to 10 years The importance of desludging can not be over emphasized since the Puraflo system is designed to treat effluent from a well functioning septic tank where a significant portion of insoluble solids have been allowed to settle out The effluent filter installed with the Puraflo syst...

Page 7: ...o system will function normally when used in vacation seasonal or intermittent homes During normal operation of the Puraflo peat fiber biofilter a stable ecosystem exists in the peat fiber media consisting of a diverse population of microorganisms and also higher life forms During a period of reduced waste waterflowtothePuraflomodules themicrobial population correspondingly decreases in the media ...

Page 8: ...faulty electrical system or pump is faulty 1 High water usage above design capacity activates the alarm float switch 2 Leaking plumbing fixtures 3 Leaking pump or septic tank 4 Broken timer or incorrect timer settings 5 Latched alarm 1 Pump and alarm failure due to circuit breaker switches being tripped to the off position by an electrical storm power surge or power failure 2 Pump and alarm fail c...

Page 9: ... meters Peat modules for any structural damage accessibility adequate ventilation excess odors insect or other pest infestations Vegetative growth over the drainfield Drainfield area for surfacing of the effluent Sample of peat biofilter effluent collected form the sampling point to check for efflu ent clarity and odor note peat biofilter effluent may have a brackish to straw color from the humic ...

Page 10: ...owner shall be notified in writing of improper system operations that cannot be corrected at the time of inspection Upon expiration of this policy our firm will offer a continuing service policy on a yearly basis to cover labor and for normal maintenance and repairs on a year by year basis Violations of warran ty include shutting off electric current to the system for more than 24 hours disconnect...

Page 11: ...ion Name Anua Environmental Products U S Inc Address PO Box 77457 Greensboro North Carolina 27417 Office Phone 336 547 9338 Toll Free Phone 1 800 PURAFLO Fax 336 547 8559 Email Address info anua us com Website Address www anua us com 9 2 Authorized Service Provider Contact Information To identify the initial service provider for your system check the labels on the control panel and fill in the tab...

Page 12: ...ndustry information Such recommendations do not constitute a warranty of satisfactory performance This LIMITED WARRANTY extends to the original retail customer of the product As herein original retail customer is defined as the purchaser who first has the plant installed or in the case of a system designed for non permanent installation the purchaser who first uses the system It is the purchaser s...

Page 13: ...ler name phone ______________________________ ______________________________ ______________________________ Service provider name phone Regulatory Authority Permit if applicable ___________________________________________________________________________________________________ ___________________________________________________________________________________________________ Notice of Transfer I t...

Reviews: