Copyright Gianni Industries, Inc. All Rights Reserved.
P-MU-DG30 Published:2009.06.15 Page: 1/ 5
DG-30 Digital Keypad / Proximity Entry system
Operation User's Manual
1. Product Characteristic:
Allows up to 150 Proximity cards / tokens or PIN codes
Tamper Switch Included
Door Reed Switch Input for Anti-Trailing
Fully Programmable via keypad and master code
Extendable from keypad only to proximity controller
Supports 26 or 34-bit Wiegand auxiliary reader
Logical memory to prevent duplication
Non-Volatile Memory
Invalid PIN Lock-out
2. Specifications:
Operating Voltage: 12 Vdc
Current Draw:
60mA Max @12VDC
Input: request-to-exit, time out reed switch contact, auxiliary reader
Relays Electric Current: 2A MAX @30Vdc
;
0.4A @ 120Vac
Memory Volume: 150 PIN codes or 100 Proximity cards/tokens and 50 PIN codes
Format: 26 or 34-bit Wiegand hexadecimal.
Relay 1 is controlled by 001~100 user slots
(
Cards or PIN codes
)
Relay 2 is controlled by 101~150 user slots
(
PIN codes
)
PIN codes: 5 digit codes only
Case Material: ABS
(
UL94V0
)
Operating Temperature: -20~+70
℃
Ambient Humidity: 5~95% relative humidity non-condensing
Visual Signals:
Red: Power on
Green: Relay activated
Tri-color LED:
Yellow: Program Mode
Red: The slot is registered
、
Lock-out
Green: This slot may register the card or PIN codes.
Factory Master Code: 12345
Invalid PIN Lock-out: The system will shut down for 60 seconds while 32 codes of
incorrectly Master Codes enrolled or PIN codes attempted.
EPROM: Non-volatile memory, System will retain all programs and codes after a total
loss of power.
Output: Dual relay, N.O./N.C./Com. Output (free voltage contact)
、
Tamper switch
Relay Activation Time:
(*
10
、*
20
)
Strike Time: 1~99 seconds
(
adjustable
)
Strike mode: Access Timer or Latch
Color: Dark gray/ Beige White