background image

 

Copyright Gianni Industries, Inc. All Rights Reserved.  
P-MU-DG30  Published:2009.06.15                                                         Page: 1/ 5

 

 

DG-30 Digital Keypad / Proximity Entry system 

Operation User's Manual

 

 

 

 

 

1.  Product Characteristic: 
 

 

Allows up to 150 Proximity cards / tokens or PIN codes 

 

Tamper Switch Included 

 

Door Reed Switch Input for Anti-Trailing 

 

Fully Programmable via keypad and master code 

 

Extendable from keypad only to proximity controller  

 

Supports 26 or 34-bit Wiegand auxiliary reader 

 

Logical memory to prevent duplication 

 

Non-Volatile Memory  

 

Invalid PIN Lock-out  

 
 
 
 
 

2.  Specifications: 

 

Operating Voltage: 12 Vdc 

 

Current Draw: 

60mA Max @12VDC 

 

Input:  request-to-exit, time out reed switch contact, auxiliary reader  

 

Relays Electric Current: 2A MAX @30Vdc 

0.4A @ 120Vac  

 

Memory Volume: 150 PIN codes or 100 Proximity cards/tokens and 50 PIN codes  

 

Format: 26 or 34-bit Wiegand hexadecimal. 

 

Relay 1 is controlled by 001~100 user slots

Cards or PIN codes

 

 

Relay 2 is controlled by 101~150 user slots

PIN codes

 

 

PIN codes: 5 digit codes only                             

 

Case Material: ABS 

UL94V0

 

 

Operating Temperature: -20~+70

 

 

Ambient Humidity: 5~95% relative humidity non-condensing 

 

Visual Signals: 

 

Red: Power on 

 

Green: Relay activated 

 

Tri-color LED: 

 

Yellow: Program Mode 

 

Red: The slot is registered

Lock-out 

 

Green: This slot may register the card or PIN codes. 

 

Factory Master Code: 12345 

 

Invalid PIN Lock-out: The system will shut down for 60 seconds while 32 codes of 
incorrectly Master Codes enrolled or PIN codes attempted. 

 

EPROM:  Non-volatile memory, System will retain all programs and codes after a total   
loss of power. 

 

Output: Dual relay, N.O./N.C./Com. Output (free voltage contact) 

Tamper switch      

 

Relay Activation Time: 

(*

10

、*

20

 

 

Strike Time: 1~99 seconds

adjustable

 

 

Strike mode: Access Timer or Latch 

 

Color: Dark gray/ Beige White 

 
 
 

Summary of Contents for DG-30

Page 1: ...ity cards tokens and 50 PIN codes Format 26 or 34 bit Wiegand hexadecimal Relay 1 is controlled by 001 100 user slots Cards or PIN codes Relay 2 is controlled by 101 150 user slots PIN codes PIN codes 5 digit codes only Case Material ABS UL94V0 Operating Temperature 20 70 Ambient Humidity 5 95 relative humidity non condensing Visual Signals Red Power on Green Relay activated Tri color LED Yellow P...

Page 2: ...IN Lock out time 60 seconds 4 Operation Instruction Enter Program Mode 1 Compose twice the master code Factory master is 12345 2 beeps and the Yellow LED will light up you are now in the programming mode 2 Note After 60 seconds if you have not entered any codes or data the system will automatically exit from the programming mode After 6 wrong attempts at the master code the lockout facility will o...

Page 3: ...codes Yellow LED blinks beep enrolled repeat B Red light comes on This slot position code is registered 1 Press deletion Green light Press the slot position code again Input 5 digit PIN codes same as Step A 2 Enter another slot card position Note 1 The codes 12345 or master code are not be used for PIN code Note 2 PIN codes operate open door random codes 5 digit PIN codes Enter To Program Relockin...

Page 4: ... after exactly 5 audible beeps otherwise all cards codes will be deleted 5 Wiring diagram 1 2 3 12V GND DATA CLK BUZZER 5V Auxiliary Reader Wiegand 26 or 34 bit Format Auxiliary Reader Data CLK Format To follow the precedent of Group 1 contacts Tamper switch contact output free voltage contact Tamper Switch Push Button FAIL SAFE LOCKING DEVICE Power Supply Re set of all system parameter Contact do...

Page 5: ... to suppress the back EMF of the strike failure to do so will damage the relay contacts and electronic components Egresses switch should be N O type Warranty The product is warranted against defects in material and workmanship while used in normal service for a period of 1 year from the date of sale to the original customer ANXELL policy is one of continual development and improvement therefore GE...

Reviews: